ESS - CAR - Comunicações em eventos científicos
Permanent URI for this collection
Browse
Browsing ESS - CAR - Comunicações em eventos científicos by Title
Now showing 1 - 10 of 29
Results Per Page
Sort Options
- AIRDOC: Smart mobile application for individualized support and monitoring of respiratory function and sounds of patients with chronic osbtructive diseasePublication . Almeida, Rute; Amaral, Rita; Jácome, Cristina; Martinho, Diogo; Vieira-Marques, Pedro; Jacinto, Tiago; Ferreira, Ana; Almeida, Ana; Martins, Constantino; Pereira, Mariana; Pereira, Ana; Valente, José; Almeida, Rafael; Vieira, Ana; Amaral, Rita; Sá-Sousa, Ana; Gonçalves, Ivânia; Rodrigues, Pedro; Alves-Correia, Magna; Freitas, Alberto; Marreiros, GoretiCurrent tools for self-management of chronic obstructive respiratory diseases (CORD) are difficult to use, not individualized and requiring laborious analysis by health professionals, discouraging their use in healthcare. There is an opportunity for cost-effective and easy-to-disseminate advanced technological solutions directed to patients and attractive to different stakeholders. The strategy of AIRDOC is to develop and integrate self-monitoring and self-managing tools, making use of the smartphone's presence in everyday life. AIRDOC intends to innovate on: i) technologies for remote monitoring of respiratory function and computerized lung auscultation; ii) coaching solutions, integrating psychoeducation, gamification and disease management support systems; and iii) management of personal health data, focusing on security, privacy and interoperability. It is expected that AIRDOC results will contribute for the innovation in CORD healthcare, with increased patient involvement and empowerment while providing quality prospective information for better clinical decisions, allowing more efficient and sustainable healthcare delivery.
- Associação entre o número de sensibilizações a aeroalergénios e parâmetros de função respiratóriaPublication . Gonçalves, I.; Pereira, A. M.; Jacinto, Tiago; Amaral, Rita; Fonseca, J. A.; Amaral, RitaO número de sensibilizações a aeroalergénios é importante na classificação fenotípica de indivíduos com patologia das vias aéreas, estando um maior número associado a maior gravidade da patologia (Amaral R et al, Allergy 2019). No entanto, a sua associação com a função respiratória não está ainda estudada.
- Automatic quality assessment of a forced expiratory manoeuvre acquired with the tablet microphonePublication . Almeida, Rute; Bernardo, Pinho; Jácome, Cristina; Teixeira, João Fonseca; Amaral, Rita; Gonçalves, Ivânia; Lopes, Filipa; Pinheiro, Ana Catarina; Jacinto, Tiago; Paixão, Cátia; Pereira, Mariana; Marques, Alda; Fonseca, João AlmeidaEvaluation of lung function is central to the management of chronic obstructive respiratory diseases. It is typically evaluated with a spirometer by a specialized health professional, who ensures the correct execution of a forced expiratory manoeuvre (FEM). Audio recording of a FEM using a smart device embedded microphone can be used to self-monitor lung function between clinical visits. The challenge of microphone spirometry is to ensure the validity and reliability of the FEM, in the absence of a health professional. In particular, the absence of a mouthpiece may allow excessive mouth closure, leading to an incorrect manoeuvre. In this work, a strategy to automatically assess the correct execution of the FEM is proposed and validated. Using 498 FEM recordings, both specificity and sensitivity attained were above 90%. This method provides immediate feedback to the user, by grading the manoeuvre in a visual scale, promoting the repetition of the FEM when needed.
- Automatic quality assessment of smart device microphone spirometryPublication . Pinho, B.; Almeida, R.; Jácome, C.; Teixeira, J. P.; Amaral, Rita; Lopes, F.; Jacinto, Tiago; Guedes, R.; Pereira, M.; Gonçalves, I.; Fonseca, J. A.; Amaral, RitaLung function tests are critical for diagnosis and monitoring of asthma and other respiratory diseases. Monitoring of lung function, in the absence of a healthcare professional, is very challenging but may be obtained through Smart Devices if automated quality assessment systems guarantee the proper technique during the forced expiratory manoeuvre. This paper describes the evaluation of one such system that uses the microphone of smart devices, regarding the initial effort of forced expiratory manoeuvres using the Back Extrapolated Volume. A health professional recorded microphone spirometry in 55 children (5-10 years), using a mobile game engineered for the purpose, and registered its quality. At least one acceptable manoeuvre was achieved for 96% of the children using a featured threshold. Using a stricter threshold of 5% of forced vital capacity, it was possible to ensure at least one acceptable manoeuvre for 69%. While the obtained results are comparable to findings in literature for regular spirometry in this age group, further work is required before we can determine whether the proposed algorithm is effective in real life.
- Caracterização da função pulmonar de bombeiros da Região Norte de PortugalPublication . Rocha, Ana; Martins, Cristiana; Baeta, CristinaOs Bombeiros estão expostos frequentemente a vários poluentes prejudicando gravemente a sua saúde respiratória. Foi realizado um estudo observacional e transversal, com o objectivo de caracterizar a função pulmonar dos bombeiros da região norte de Portugal. A amostra foi constituída por 44 Bombeiros de Valongo e Rebordosa. Todos os participantes preencheram um questionário, executaram espirometrias e mediram o monóxido de carbono. Verificou-se uma elevada prevalência de hábitos tabágicos, bem como da carga tabágica. A percentagem de alterações espirométricas foi de 38,6% e a utilização de protecção respiratória revelou-se praticamente inexistente nos incêndios florestais.
- Combined image-based approach for monitoring the adherence to inhaled medicationsPublication . Vieira-Marques, Pedro; Teixeira, João Fonseca; Valente, José; Pinho, Bernardo; Guedes, Rui; Almeida, Rute; Jácome, Cristina; Pereira, Ana; Jacinto, Tiago; Amaral, Rita; Gonçalves, Ivânia; Sousa, Ana Sá; Couto, Mariana; Magalhães, Manuel; Bordalo, Diana; Silva, Luís Nogueira; Fonseca, J. AlmeidaThe adherence to inhaled controller medications is of critical importance to achieve good clinical results in patients with chronic respiratory diseases. To objectively verify the adherence, a detection tool was previously developed and integrated in the mobile application InspirerMundi, based on image processing methods. In this work, a new approach for enhanced adherence verification was developed. In a first phase template matching is employed to confirm the inhaler positioning and to locate the dose counter. In a second phase Google ML Kit framework is used for the detection of each numerical dose in the dose counter. The proposed approach was validated through a new detection tool pilot implementation, using a set of images collected by patients using the application in their daily life. Performance of each of the two phases was evaluated for a set of commonly used inhaler devices. Promising results were achieved showing the potential of mobile embedded sensors without the need for external devices.
- Comparação dos hábitos tabágicos entre grupos geracionais na ESTSPPublication . Pereira, Joana; Martins, Cristiana; Baeta, CristinaO tabagismo é um dos principais problemas de saúde pública. Foi realizado um estudo transversal, descritivo e observacional, com o objectivo de caracterizar os hábitos tabágicos em dois grupos geracionais da Escola Superior de Tecnologia da Saúde do Porto (ESTSP). Aplicou-se um questionário, adaptado do Inquérito Nacional de Saúde 2005/2006 a uma amostra de dois grupos: adultos e jovens. A prevalência total do tabagismo foi de 32,2%, sendo superior no sexo feminino (35%), nos jovens (39,2%) e no curso de Audiologia (17,5%). A elevada prevalência de fumadores demonstra a necessidade de adoptar medidas eficazes na prevenção do tabagismo.
- A comparison of unsupervised methods based on dichotomous data to identify clusters of airways symptoms: latent class analysis and partitioning around medoids methodsPublication . Amaral, Rita; Jacinto, Tiago; Pereira, Ana; Almeida, Rute; Fonseca, JoãoLatent class analysis (LCA) and partitioning around medoids (PAM) are popular data-driven methods for partitioning objects based on dichotomous data, remaining not clear which is better for large epidemiological datasets. Hence, we compared these methods in the identification of clusters of subjects with airways symptoms, using a large population-based data from the U.S. National Health and Nutrition Examination Surveys (NHANES).
- Data-driven prescription patterns in patients under maintenance treatment for respiratory diseases from the Portuguese prescription databasePublication . Sá-Sousa, Ana; Amaral, Rita; Almeida, Rute; Freitas, Alberto; Fonseca, João AWe aimed to identify prescription patterns in respiratory patients using an unsupervised (data-driven) method, in a random sample of patients aged >14 years (n=8799), retrieved from the Portuguese Electronic Medical Prescription database. Respiratory patients were defined if >2 packs of maintenance treatment for respiratory diseases were prescribed in 2016. We analysed all the prescriptions (n=39810) for respiratory diseases and exacerbations by medication type. Two-step clustering was based on the presence of ICS, LABA, LTRA, LAMA, LABA, SABA, SAMA and on the speciality of prescriber.
- Efetividade da Perfusão Regional Hipertérmica em doentes com diagnóstico de sarcoma nas extremidadesPublication . Castro, Fábio; Baeta, Cristina; Narciso, Jorge; Jacinto, Tiago; Ribeiro, MatildeO sarcoma é uma neoplasia dos tecidos moles com incidência significativa nos membros, evoluindo rapidamente para metastização regional/sistémica. A Perfusão Regional Hipertérmica (PRH) é aplicada como tratamento paliativo/adjuvante. Avaliar o tipo de resposta clínica, taxa de amputação e sobrevivência nos doentes com diagnóstico de sarcoma das extremidades submetidos a PRH, em função do tipo histológico e excisão/não-excisão da lesão. Estudo observacional retrospectivo. A amostra incluiu todos os pacientes com sarcoma submetidos a PRH entre 01/10/1990 e 31/12/2017. As variáveis estudadas foram a resposta clínica (completa, parcial, sem-resposta, progressão), taxa de amputação, sobrevivência (um, dois, cinco anos). A resposta clínica foi variável dependente em relação à PRH e independente na análise da taxa de amputação. Incluíram-se 53 doentes, com média de idade 57(±17) anos, 50% do sexo masculino, 76% com lesões nos membros inferiores. A progressão da doença foi a resposta clínica mais frequente (33%), sendo a resposta global (completa+parcial) de 49%. O sarcoma das células claras e o angiossarcoma apresentaram resposta global mais elevada, 80% e 71% respetivamente. Verificaram-se diferenças estatisticamente significativas (p=0,048) nas taxas de amputação entre os grupos que efetuaram ou não excisão da lesão, após não-resposta à PRH. A taxa de sobrevivência a 1 ano foi 57%, aos 2 anos foi 40% e aos 5 anos foi 30%, não existindo diferenças estatisticamente significativas entre os tipos histológicos (p=0,397, p=0,400 e p=0,276). Metade destes doentes obteve resposta global. A taxa de amputação foi 35% e a mediana da sobrevivência foi 1,2 anos.
- «
- 1 (current)
- 2
- 3
- »