  • Electrochemical sensing of the thyroid hormone thyronamine (T0AM) via molecular imprinted polymers (MIPs)
    Publication . Pacheco, João; Rebelo, Patrícia; Cagide, Fernando; Gonçalves, Luís Moreira; Borges, Fernanda; Rodrigues, José António; Delerue-Matos, Cristina
    Recent studies have shown that besides the well-known T3 (triiodothyronine) and T4 (thyroxine) there might be other important thyroid hormones, in particular T0AM (thyronamine) and T1AM (3-iodothyronamine). The absence of a large number of studies showing their precise importance might be explained by the limited number of analytical methodologies available. This work aims to show an electroanalytical alternative making use of electropolymerized molecularly imprinted polymer (MIPs). The MIPs' polymerization is performed on the surface of screen-printed carbon electrodes (SPCEs), using 4-aminobenzoic acid (4-ABA) as the building and functional monomer and the analyte T0AM as the template. The step-by-step construction of the SPCE-MIP sensor was studied by cyclic voltammetry (CV) and by electrochemical impedance spectroscopy (EIS). After optimization, by means of square-wave voltammetry, the SPCE-MIP showed suitable selectivity (in comparison with other thyroid hormones and catechol amines), repeatability (intra-day of 3.9%), a linear range up to 10 μmol L-1 (0.23 × 103 μg dL-1) with an r2 of 0.998 and a limit of detection (LOD) and quantification (LOQ) of 0.081 and 0.27 μmol L-1 (1.9 and 6.2 μg dL-1), respectively.
  • Breast cancer biomarker (HER2-ECD) detection using a molecularly imprinted electrochemical sensor
    Publication . Pacheco, João; Rebelo, Patrícia; Freitas, Maria; Nouws, Henri; Delerue-Matos, Cristina
    The extracellular domain of the human epidermal growth factor receptor 2 (HER2-ECD) is a protein breast cancer biomarker. Its quantification in peripheral blood could provide an important contribution to diagnostics and patient follow-up. In this work an electrochemical molecularly imprinted polymer (MIP) sensor for the quantification of HER2-ECD was developed. The MIP was electropolymerized by cyclic voltammetry using a solution containing phenol and HER2-ECD on a screen-printed gold electrode (AuSPE). The sensor was characterized by cyclic voltammetry and electrochemical impedance spectroscopy. The analysis of HER2-ECD was performed by differential pulse voltammetry using ([Fe(CN)6]3−/4−as redox probe. The linear range was established in the concentration interval from 10 to 70 ng/mL HER2-ECD, with a limit of detection of 1.6 ng/L and a limit of quantification of 5.2 ng/mL. Through the analysis of other protein biomarkers, the MIP sensor was found to be selective. Furthermore, these proteins did not interfere in the analysis of the selected biomarker. The developed sensor was used for the analysis of spiked human serum samples, providing adequate recovery values and precise results. The outcomes of this study indicate that the developed MIP sensor could be useful in the non-invasive analysis of HER2-ECD in breast cancer patients.
  • Molecularly imprinted electrochemical sensor prepared on a screen printed carbon electrode for naloxone detection
    Publication . Lopes, Frederico; Pacheco, João; Rebelo, Patrícia; Delerue-Matos, Cristina
    Naloxone (NLX) is a pharmaceutical used as opioid antagonist. A molecular imprinted polymer electrochemical sensor for simple and rapid detection of NLX was prepared through the modification of commercial available screen printed carbon electrode (SPCE). The SPCE was modified with multi-walled carbon nanotubes (MWCNT) by drop coating to increase the signal response and improve the sensitivity. The MIP preparation was carried out via in situ electropolymerization using 4-aminobenzoic acid (4-ABA) as functional monomer. The morphology of the obtained sensor was characterized by scanning electron microscopy (SEM). Several parameters controlling the preparation and performance of the MIP sensor were studied and optimized. The electrochemical behavior of NLX at MIP and control non-imprinted (NIP) sensor was evaluated by differential pulse voltammetry (DPV), demonstrating a better MIP response and the success of the imprinting. The proposed MIP/MWCNT/SPCE sensor showed a linear relationship between peak current intensity and NLX concentration in the range between 0.25 and 10.0 μM, with limits of detection (LOD) and quantification (LOQ) of 0.20 μM and 0.67 μM respectively. The repeatability and reproducibility were also tested with relative standard deviations (RSD) of 4.6 and 9.6% respectively. Moreover, the applicability of the method was successfully confirmed with detection of NLX in biological samples (urine and human serum). The sensor is promising to be used for screening NLX in point-of-care people with opioid overdose.
  • Electrochemical sensing of ecstasy with electropolymerized molecularly imprinted poly(o-phenylenediamine) polymer on the surface of disposable screen-printed carbon electrodes
    Publication . Couto, Rosa A.S.; Costa, Séfora S.; Mounssef, Bassim; Pacheco, João; Fernandes, Eduarda; Carvalho, Félix; Rodrigues, Cecília M.P.; Delerue-Matos, Cristina; Braga, Ataualpa A.C.; Moreira Gonçalves, Luís; Quinaz, M. Beatriz
    This study demonstrates the ability of an electrochemical sensor based on molecularly imprinted polymers (MIPs) to selectively quantify 3,4-methylenedioxymethamphetamine (MDMA), also known as ecstasy, in biological samples. The device was constructed using ortho-phenylenediamine (o-PD) as the MIP’s building monomer at the surface of a screen-printed carbon electrode (SPCE). The step-by-step construction of the SPCE-MIP sensor was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Density functional theory (DFT) calculations and modelling were performed not only to understand template-monomer interaction but also to comprehend which possible polymer structure - linear or ramified poly(o-PD) – indeed interacts with the analyte. The prepared sensor worked by directly measuring the MDMA oxidation signal through square-wave voltammetry (SWV) after an incubation period of 10 min. Several parameters were optimized, such as the monomer/template ratio, the number of electropolymerization scanning cycles, and the incubation period, to obtain the best sensing efficiency. Optimized sensors exhibited suitable selectivity, repeatability (2.6%), reproducibility (7.7%) and up to one month of stable response. A linear range up to 0.2 mmol L−1 was found with an r2 of 0.9990 and a limit of detection (LOD) and quantification (LOQ) of 0.79 and 2.6 μmol L−1 (0.15 and 0.51 μg mL−1), respectively. The proposed sensor was successfully applied to human blood serum and urine samples, showing its potential for application in medicine and in forensic sciences.
  • Molecularly imprinted electrochemical sensor for the point-of-care detection of a breast cancer biomarker (CA 15-3)
    Publication . Pacheco, João; Silva, Marta S.V.; Freitas, Maria; Nouws, Henri; Delerue-Matos, Cristina
    The incidence of breast cancer has been increasing over the years. To control and monitor this disease several tumor biomarkers have been proposed for early diagnosis, patient follow-up and/or treatment guidance. The only serum breast cancer biomarker in current use is the cancer antigen 15-3 (CA 15-3). In this work a molecularly imprinted polymer (MIP)-based electrochemical (voltammetric) sensor to monitor breast cancer was developed, based on direct surface imprinting of CA 15-3 on a screen-printed gold electrode (Au-SPE). The imprinting was performed in two steps: (1) adsorption of CA 15-3 on the surface of the Au-SPE and (2) electropolymerization of 2-aminophenol around the adsorbed protein. After extraction of the imprinted protein voltammetric analysis was conducted using hexacyanoferrate(II/III) as redox probe, measuring the signals before and after protein binding. The sensor was characterized by voltammetric techniques and electrochemical impedance spectroscopy, and the analytical responses of imprinted and non-imprinted polymer sensors were studied. A linear relationship between the peak current intensity of the redox probe and the logarithm of CA 15-3 concentration was established between 5 and 50 U mL−1, achieving a limit of detection of 1.5 U mL−1. The prepared MIP-sensor provides fast (15 min) analysis and is cheap, easy to prepare, disposable and could easily be integrated in small portable point-of care devices.
  • Magnetic dispersive micro solid-phase extraction and gas chromatography determination of organophosphorus pesticides in strawberries
    Publication . Fernandes, Virgínia Cruz; Freitas, Maria; Pacheco, João; Oliveira, José Maria; Domingues, Valentina; Delerue-Matos, Cristina
    Magnetic nanoparticles (MNPs) with different sizes and characteristics were synthesized to be used as a QuEChERS sorbents for the determination of seven organophosphorus pesticides (OPPs) in strawberries by gas chromatography analysis with flame photometric and mass spectrometry detection. To achieve the optimum conditions of modified QuEChERS procedure several parameters affecting the cleanup efficiency including the amount of the sorbents and cleanup time were investigated. The results were compared with classical QuEChERS methodologies and the modified QuEChERS procedure using MNPs showed the better performance. Under the optimum conditions of the new methodology, three spiking levels (25, 50 and 100 μg kg-1) were evaluated in a strawberry sample. The results showed that the average recovery was 93% and the relative standard deviation was less than 12%. The enrichment factor ranged from 111 to 145%. The good linearity with coefficients of determination of 0.9904-0.9991 was obtained over the range of 25-250 μg kg-1 for 7 OPPs. It was determined that the MNPs have an excellent function as sorbent when purified even using less amount of sorbents and the magnetic properties allowed non-use of the centrifugation in cleanup step. The new methodology was applied in strawberry samples from conventional and organic farming. The new sorbents were successfully applied for extraction and determination of OPPs in strawberries.