Publication
Automatic quality assessment of a forced expiratory manoeuvre acquired with the tablet microphone
dc.contributor.author | Almeida, Rute | |
dc.contributor.author | Bernardo, Pinho | |
dc.contributor.author | Jácome, Cristina | |
dc.contributor.author | Teixeira, João Fonseca | |
dc.contributor.author | Amaral, Rita | |
dc.contributor.author | Gonçalves, Ivânia | |
dc.contributor.author | Lopes, Filipa | |
dc.contributor.author | Pinheiro, Ana Catarina | |
dc.contributor.author | Jacinto, Tiago | |
dc.contributor.author | Paixão, Cátia | |
dc.contributor.author | Pereira, Mariana | |
dc.contributor.author | Marques, Alda | |
dc.contributor.author | Fonseca, João Almeida | |
dc.date.accessioned | 2021-01-05T15:56:57Z | |
dc.date.available | 2021-01-05T15:56:57Z | |
dc.date.issued | 2020-08-01 | |
dc.description.abstract | Evaluation of lung function is central to the management of chronic obstructive respiratory diseases. It is typically evaluated with a spirometer by a specialized health professional, who ensures the correct execution of a forced expiratory manoeuvre (FEM). Audio recording of a FEM using a smart device embedded microphone can be used to self-monitor lung function between clinical visits. The challenge of microphone spirometry is to ensure the validity and reliability of the FEM, in the absence of a health professional. In particular, the absence of a mouthpiece may allow excessive mouth closure, leading to an incorrect manoeuvre. In this work, a strategy to automatically assess the correct execution of the FEM is proposed and validated. Using 498 FEM recordings, both specificity and sensitivity attained were above 90%. This method provides immediate feedback to the user, by grading the manoeuvre in a visual scale, promoting the repetition of the FEM when needed. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | Almeida, R., Pinho, B., Jácome, C., Teixeira, J. F., Amaral, R., Gonçalves, I., Lopes, F., Pinheiro, A. C., Jacinto, T., Paixão, C., Pereira, M., Marques, A., & Almeida Fonseca, J. (2020). Automatic Quality Assessment of a Forced Expiratory Manoeuvre Acquired with the Tablet Microphone. Em J. Henriques, N. Neves, & P. de Carvalho (Eds.), XV Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 (pp. 1394–1398). Springer International Publishing. https://doi.org/10.1007/978-3-030-31635-8_170 | |
dc.identifier.doi | 10.1007/978-3-030-31635-8_170 | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.22/16656 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Springer | pt_PT |
dc.relation.publisherversion | https://link.springer.com/chapter/10.1007/978-3-030-31635-8_170 | pt_PT |
dc.subject | Lung function monitoring | pt_PT |
dc.subject | Smart device | pt_PT |
dc.subject | Signal quality | pt_PT |
dc.title | Automatic quality assessment of a forced expiratory manoeuvre acquired with the tablet microphone | pt_PT |
dc.type | conference object | |
dspace.entity.type | Publication | |
person.familyName | Amaral | |
person.givenName | Rita | |
person.identifier | R-00H-83K | |
person.identifier.ciencia-id | 1A1E-751F-50F0 | |
person.identifier.ciencia-id | ED1E-5481-48E1 | |
person.identifier.orcid | 0000-0002-0233-830X | |
person.identifier.orcid | 0000-0002-7897-1101 | |
person.identifier.rid | E-5535-2017 | |
person.identifier.scopus-author-id | 56067841600 | |
rcaap.rights | closedAccess | pt_PT |
rcaap.type | conferenceObject | pt_PT |
relation.isAuthorOfPublication | 790fdd33-acdb-4dfe-88dc-38538486c9b3 | |
relation.isAuthorOfPublication | d8696cf3-a961-4d88-963a-cefd61572ae3 | |
relation.isAuthorOfPublication.latestForDiscovery | 790fdd33-acdb-4dfe-88dc-38538486c9b3 |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- COM_Rita_Amaral.pdf
- Size:
- 734.41 KB
- Format:
- Adobe Portable Document Format