Repository logo
 
No Thumbnail Available
Publication

Breast DWI at 3 T: influence of the fat-suppression technique on image quality and diagnostic performance

Use this identifier to reference this record.
Name:Description:Size:Format: 
ART_LuísaNogueira_2015.pdf514.17 KBAdobe PDF Download

Advisor(s)

Abstract(s)

Aim To evaluate two fat-suppression techniques: short tau inversion recovery (STIR) and spectral adiabatic inversion recovery (SPAIR) regarding image quality and diagnostic performance in diffusion-weighted imaging (DWI) of breast lesions at 3 T. Materials and methods Ninety-two women (mean age 48 ± 12.1 years; range 21–78 years) underwent breast MRI. Two DWI pulse sequences, with b-values (50 and 1000 s/mm2) were performed with STIR and SPAIR. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), suppression homogeneity, and apparent diffusion coefficient (ADC) values were quantitatively assessed for each technique. Values were compared between techniques and lesion type. Receiver operating characteristics (ROC) analysis was used to evaluate lesion discrimination. Results One hundred and fourteen lesions were analysed (40 benign and 74 malignant). SNR and CNR were significantly higher for DWI-SPAIR; fat-suppression uniformity was better for DWI-STIR (p < 1 × 10−4). ADC values for benign and malignant lesions and normal tissue were 1.92 × 10−3, 1.18 × 10−3, 1.86 × 10−3 s/mm2 for DWI-STIR and 1.80 × 10−3, 1.11 × 10−3, 1.79 × 10−3 s/mm2 for SPAIR, respectively. Comparison between fat-suppression techniques showed significant differences in mean ADC values for benign (p = 0.013) and malignant lesions (p = 0.001). DWI-STIR and -SPAIR ADC cut-offs were 1.42 × 10−3 and 1.46 × 10−3 s/mm2, respectively. Diagnostic performance for DWI-STIR versus SPAIR was: accuracy (81.6 versus 83.3%), area under curve (87.7 versus 89.2%), sensitivity (79.7 versus 85.1%), and specificity (85 versus 80%). Positive predictive value was similar. Conclusion The fat-saturation technique used in the present study may influence image quality and ADC quantification. Nevertheless, STIR and SPAIR techniques showed similar diagnostic performances, and therefore, both are suitable for use in clinical practice.

Description

Keywords

Breast Breast Neoplasms Contrast Media Diffusion Magnetic Resonance Imaging Image Enhancement Image Processing, Computer-Assisted ROC Curve Reproducibility of Results Sensitivity and Specificity Signal-To-Noise Ratio

Citation

Research Projects

Organizational Units

Journal Issue

Publisher

Elsevier

CC License

Altmetrics