Repository logo
 
Publication

Breast DWI at 3 T: influence of the fat-suppression technique on image quality and diagnostic performance

dc.contributor.authorNogueira, Luisa
dc.contributor.authorBrandão, Sofia
dc.contributor.authorNunes, Rita G.
dc.contributor.authorFerreira, Hugo Alexandre
dc.contributor.authorLoureiro, Joana
dc.contributor.authorRamos, Isabel
dc.date.accessioned2019-07-01T16:16:50Z
dc.date.available2019-07-01T16:16:50Z
dc.date.issued2015
dc.description.abstractAim To evaluate two fat-suppression techniques: short tau inversion recovery (STIR) and spectral adiabatic inversion recovery (SPAIR) regarding image quality and diagnostic performance in diffusion-weighted imaging (DWI) of breast lesions at 3 T. Materials and methods Ninety-two women (mean age 48 ± 12.1 years; range 21–78 years) underwent breast MRI. Two DWI pulse sequences, with b-values (50 and 1000 s/mm2) were performed with STIR and SPAIR. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), suppression homogeneity, and apparent diffusion coefficient (ADC) values were quantitatively assessed for each technique. Values were compared between techniques and lesion type. Receiver operating characteristics (ROC) analysis was used to evaluate lesion discrimination. Results One hundred and fourteen lesions were analysed (40 benign and 74 malignant). SNR and CNR were significantly higher for DWI-SPAIR; fat-suppression uniformity was better for DWI-STIR (p < 1 × 10−4). ADC values for benign and malignant lesions and normal tissue were 1.92 × 10−3, 1.18 × 10−3, 1.86 × 10−3 s/mm2 for DWI-STIR and 1.80 × 10−3, 1.11 × 10−3, 1.79 × 10−3 s/mm2 for SPAIR, respectively. Comparison between fat-suppression techniques showed significant differences in mean ADC values for benign (p = 0.013) and malignant lesions (p = 0.001). DWI-STIR and -SPAIR ADC cut-offs were 1.42 × 10−3 and 1.46 × 10−3 s/mm2, respectively. Diagnostic performance for DWI-STIR versus SPAIR was: accuracy (81.6 versus 83.3%), area under curve (87.7 versus 89.2%), sensitivity (79.7 versus 85.1%), and specificity (85 versus 80%). Positive predictive value was similar. Conclusion The fat-saturation technique used in the present study may influence image quality and ADC quantification. Nevertheless, STIR and SPAIR techniques showed similar diagnostic performances, and therefore, both are suitable for use in clinical practice.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.1016/j.crad.2014.11.012pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.22/14209
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherElsevierpt_PT
dc.relationSFRH/BD/50027/2009pt_PT
dc.relationStrategic Project - UI 645 - 2011-2012
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S0009926014005224?via%3Dihubpt_PT
dc.subjectBreastpt_PT
dc.subjectBreast Neoplasmspt_PT
dc.subjectContrast Mediapt_PT
dc.subjectDiffusion Magnetic Resonance Imagingpt_PT
dc.subjectImage Enhancementpt_PT
dc.subjectImage Processing, Computer-Assistedpt_PT
dc.subjectROC Curvept_PT
dc.subjectReproducibility of Resultspt_PT
dc.subjectSensitivity and Specificitypt_PT
dc.subjectSignal-To-Noise Ratiopt_PT
dc.titleBreast DWI at 3 T: influence of the fat-suppression technique on image quality and diagnostic performancept_PT
dc.typejournal article
dspace.entity.typePublication
oaire.awardTitleStrategic Project - UI 645 - 2011-2012
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/PEst-OE%2FSAU%2FUI0645%2F2011/PT
oaire.citation.endPage294pt_PT
oaire.citation.issue3pt_PT
oaire.citation.startPage286pt_PT
oaire.citation.titleClinical Radiologypt_PT
oaire.citation.volume70pt_PT
oaire.fundingStream6817 - DCRRNI ID
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.nameFundação para a Ciência e a Tecnologia
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isProjectOfPublication5b115a5c-07c5-4f80-af5e-d815e8d8d51c
relation.isProjectOfPublication.latestForDiscovery5b115a5c-07c5-4f80-af5e-d815e8d8d51c

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ART_LuísaNogueira_2015.pdf
Size:
514.17 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: