Repository logo
 
Publication

Stress analysis of the tympanic membrane through image

dc.contributor.authorGarbe, Carolina
dc.contributor.authorParente, M. P. L.
dc.contributor.authorMartins, Pedro Alexandre Lopes de Sousa
dc.contributor.authorJorge, Renato Natal
dc.contributor.authorGentil, Fernanda
dc.contributor.authorPaço, João
dc.date.accessioned2024-02-28T13:12:45Z
dc.date.available2024-02-28T13:12:45Z
dc.date.issued2018
dc.description.abstractTo better understand the ear functioning, a biomechanical study of the tympanic ossicular chain of the middle ear was made. This chain consists of the tympanic membrane (which has 3 layers), three ossicles (malleus, incus and stapes), six ligaments, tendons and respective two muscles. The objective of this study was to analyze the stresses of the tympanic membrane through images, allowing a comparison of the different frequencies used. A geometric model of the tympanic membrane and ossicles was built through images of Computerized Axial Tomography (CAT). The discretization of this model was done using the finite element method, based on the ABAQUS software. The mechanical properties were obtained from previous work. The results were compared in the dynamic analysis of the tympanic ossicular chain for a frequency range between 100 Hz and 10 kHz, for a sound pressure level of 105 dB SPL, applied on the tympanic membrane. We can observe differences for each frequency in the tympanic membrane.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationGarbe, C., Parente, M., Martins, P., Jorge, R. N., Gentil, F., & Paço, J. (2018). Stress analysis of the tympanic membrane through image. Em J. M. R. S. Tavares & R. M. N. Jorge (Eds.), Computational Vision and Medical Image Processing: VipIMAGE 2011 (1a, pp. 311–314). Routledge/Taylor & Francis. https://www.routledge.com/Computational-Vision-and-Medical-Image-Processing-VipIMAGE-2011/Tavares-Natal-Jorge/p/book/9781138112544pt_PT
dc.identifier.isbn978-113-811-254-4
dc.identifier.urihttp://hdl.handle.net/10400.22/25092
dc.language.isoengpt_PT
dc.publisherRoutledge/Taylor & Francispt_PT
dc.relationMinistry of Science and Higher Education (FCT-Portugal) through project "Estudo bio-computacional do zumbido" (PTDC/SAU-BEB/104992/2008).pt_PT
dc.relation.publisherversionhttps://www.routledge.com/Computational-Vision-and-Medical-Image-Processing-VipIMAGE-2011/Tavares-Natal-Jorge/p/book/9781138112544pt_PT
dc.subjectTympanic membranept_PT
dc.subjectComputerized Axial Tomographypt_PT
dc.titleStress analysis of the tympanic membrane through imagept_PT
dc.typebook part
dspace.entity.typePublication
oaire.citation.conferencePlaceOlhão, Algarve - Portugalpt_PT
oaire.citation.endPage314pt_PT
oaire.citation.issuept_PT
oaire.citation.startPage311pt_PT
oaire.citation.titleComputational Vision and Medical Image Processing: VipIMAGE 2011, Proceedings of VipIMAGE2011 - Third eccomas thematic conference on computational vision and medical image processingpt_PT
person.familyNameGentil Costa
person.givenNameMaria Fernanda
person.identifier.ciencia-id8A1B-AB35-07A4
person.identifier.orcid0000-0002-6521-3475
rcaap.rightsclosedAccesspt_PT
rcaap.typebookPartpt_PT
relation.isAuthorOfPublicationa322f388-4cfc-4430-ae6f-ba10bf53758f
relation.isAuthorOfPublication.latestForDiscoverya322f388-4cfc-4430-ae6f-ba10bf53758f

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
CAP_Fernanda Gentil 1.pdf
Size:
691.75 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: