Repository logo
 
Publication

Preventing exposure to cytotoxic drugs by analysing cyclophosphamide residues in the manipulation areas of a northern portuguese hospital

dc.contributor.authorNuro, Ali
dc.contributor.authorCarmo, Helena
dc.contributor.authorCorreia, Patrícia
dc.contributor.authorLeitão, Mariana
dc.contributor.authorRocha, Luísa
dc.contributor.authorFernando, Cristina
dc.contributor.authorMoreira, Fernando
dc.date.accessioned2023-09-12T15:32:03Z
dc.date.available2023-09-12T15:32:03Z
dc.date.issued2022-05
dc.description.abstractThe manipulation of cytotoxic agents has been increasing as chemotherapy remains the first line treatment for several malignant diseases of growing incidence. However, cytotoxic agents such as cyclophosphamide do not specifically target cancer cells, being therefore able to harm the professionals that prepare them. To prevent occupational exposure, an adequate monitoring of the working environment is warranted. The present study aimed at validating an analytical method for the evaluation of the presence of cyclophosphamide in the surface of three different rooms of a northern Portuguese hospital, in which cytotoxic drugs are received or manipulated. The extraction procedure consisted of wiping with a 100cm2 gauze moistened with ethyl-acetate followed by mixing with 15mL methanol: acetonitrile: water (25:10:65) and filtration with a PTFE 0.2µm filter. The samples were then analysed by HPLC-DAD (205nm), with the separation being obtained with a C18 column. The analytical method was validated regarding linearity, intra-day (92-98%) and inter-day (91-98%) precision, accuracy (80-106%), recovery (97-114%) and sensibility (LOD = 0.089 µg/cm2; LOQ = 0.269 µg/cm2). A total of 50 real samples were analysed and all of them presented values below the LOD. Despite using analytical methods with lower sensibility than the one herein presented, previous published studies about the presence of cytotoxic drugs on surfaces of other Portuguese hospitals revealed severe contamination in the manipulation areas. These negative results likely indicate that in this hospital the preparation protocols efficiently limit exposure, further evidencing the importance of complying with the guidelines. By adopting these procedures, it is possible to eliminate or at least greatly limit the occupational exposure to cytotoxic drugs, by nurses, pharmacy technicians and pharmaceutics. Analytical tools that efficiently monitor contamination are a helpful tool to monitor and prevent hazardous exposure.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationNuro, A., Carmo, H., Correia, P., Leitão, M., Rocha, L., Fernando, C., & Moreira, F. (2022, maio). Preventing exposure to cytotoxic drugs by analysing cyclophosphamide residues in the manipulation areas of a northern Portuguese hospital [Comunicação oral]. 15º Encontro de Investigação Jovem da U.Porto, Porto.pt_PT
dc.identifier.isbn978-989-746-329-7
dc.identifier.urihttp://hdl.handle.net/10400.22/23527
dc.language.isoengpt_PT
dc.publisherUniversidade do Portopt_PT
dc.relation.publisherversionhttps://www.up.pt/ijup/wp-content/uploads/sites/892/2023/05/Livro_de_Resumos_versao_final-rev2.pdfpt_PT
dc.titlePreventing exposure to cytotoxic drugs by analysing cyclophosphamide residues in the manipulation areas of a northern portuguese hospitalpt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlacePortopt_PT
oaire.citation.startPage60pt_PT
oaire.citation.title15º Encontro de Investigação Jovem da U.Portopt_PT
person.familyNameCorreia
person.familyNameMoreira
person.givenNamePatrícia Carla dos Santos Correia
person.givenNameFernando
person.identifier2947760
person.identifier.ciencia-id221F-5A5F-BFC9
person.identifier.ciencia-id5F16-AB92-94D0
person.identifier.orcid0000-0001-7869-7977
person.identifier.orcid0000-0002-3452-1459
rcaap.rightsopenAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublication655ab14f-f60f-42c5-8c8a-19d5257ff5f6
relation.isAuthorOfPublication81213e80-09a5-4655-93dc-e54199edb2fe
relation.isAuthorOfPublication.latestForDiscovery655ab14f-f60f-42c5-8c8a-19d5257ff5f6

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
COM_Patrícia Correia.pdf
Size:
179.39 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: