Publication
Chlormequat selective electrodes: construction, evaluation and application at FIA systems
dc.contributor.author | Ferreira Sales, Maria Goreti | |
dc.contributor.author | Lino, Nuno F. M. C. | |
dc.contributor.author | Paíga, Paula | |
dc.date.accessioned | 2013-11-27T16:33:08Z | |
dc.date.available | 2013-11-27T16:33:08Z | |
dc.date.issued | 2003 | |
dc.description.abstract | A flow injection analysis (FIA) system having a chlormequat selective electrode is proposed. Several electrodes with poly(vinyl chloride) based membranes were constructed for this purpose. Comparative characterization suggestedthe use of membrane with chlormequat tetraphenylborate and dibutylphthalate. On a single-line FIA set-up, operating with 1x10-2 mol L-1 ionic strength and 6.3 pH, calibration curves presented slopes of 53.6±0.4mV decade-1 within 5.0x10-6 and1.0x10-3 mol L-1, andsquaredcorrelation coefficients >0.9953. The detection limit was 2.2x10-6 mol L-1 and the repeatability equal to ±0.68mV (0.7%). A dual-channel FIA manifold was therefore constructed, enabling automatic attainment of previous ionic strength andpH conditions and thus eliminating sample preparation steps. Slopes of 45.5±0.2mV decade -1 along a concentration range of 8.0x10-6 to 1.0x10-3 mol L-1 with a repeatability ±0.4mV (0.69%) were obtained. Analyses of real samples were performed, and recovery gave results ranging from 96.6 to 101.1%. | por |
dc.identifier | 10.1080/0306731031000076878 | |
dc.identifier.doi | 10.1080/0306731031000076878 | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.22/3006 | |
dc.language.iso | eng | por |
dc.peerreviewed | yes | por |
dc.publisher | Taylor & Francis | por |
dc.relation.ispartofseries | International Journal of Environmental Analytical Chemistry; Vol.83, Issue 4 | |
dc.relation.publisherversion | http://www.tandfonline.com/doi/abs/10.1080/0306731031000076878#.UpYVnEr6Q25 | por |
dc.subject | Chlormequat | por |
dc.subject | Growth regulator | por |
dc.subject | Pesticides | por |
dc.subject | Potentiometry | por |
dc.subject | Ion-selective electrode | por |
dc.subject | FIA | por |
dc.title | Chlormequat selective electrodes: construction, evaluation and application at FIA systems | por |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 305 | por |
oaire.citation.issue | Issue 4 | |
oaire.citation.startPage | 295 | por |
oaire.citation.title | International Journal of Environmental Analytical Chemistry | por |
oaire.citation.volume | Vol. 83 | por |
person.familyName | Ferreira Sales | |
person.familyName | Paíga | |
person.givenName | Maria Goreti | |
person.givenName | Paula | |
person.identifier | 826970 | |
person.identifier | 1668889 | |
person.identifier.ciencia-id | E31F-1630-42BB | |
person.identifier.ciencia-id | 331A-5D6A-D3C8 | |
person.identifier.orcid | 0000-0001-9936-7336 | |
person.identifier.orcid | 0000-0002-9593-1355 | |
person.identifier.rid | K-9199-2013 | |
person.identifier.rid | Q-4930-2018 | |
person.identifier.scopus-author-id | 7005174717 | |
person.identifier.scopus-author-id | 6506638953 | |
rcaap.rights | openAccess | por |
rcaap.type | article | por |
relation.isAuthorOfPublication | b6d3a2d0-608a-4a92-834b-8d7b29069fef | |
relation.isAuthorOfPublication | 4a0677dc-0b54-4831-aa9a-4a73f0df911d | |
relation.isAuthorOfPublication.latestForDiscovery | 4a0677dc-0b54-4831-aa9a-4a73f0df911d |