Repository logo
 
Publication

Apparent diffusion coefficient in the analysis of prostate cancer: determination of optimal b-value pair to differentiate normal from malignant tissue

dc.contributor.authorAdubeiro, Nuno
dc.contributor.authorNogueira, Maria Luísa
dc.contributor.authorNunes, Rita G.
dc.contributor.authorFerreira, Hugo Alexandre
dc.contributor.authorRibeiro, Eduardo
dc.contributor.authorLa Fuente, José Maria Ferreira
dc.date.accessioned2019-06-27T16:42:00Z
dc.date.available2019-06-27T16:42:00Z
dc.date.issued2018
dc.description.abstractPurpose Determining optimal b-value pair for differentiation between normal and prostate cancer (PCa) tissues. Methods Forty-three patients with diagnosis or PCa symptoms were included. Apparent diffusion coefficient (ADC) was estimated using minimum and maximum b-values of 0, 50, 100, 150, 200, 500 s/mm2 and 500, 800, 1100, 1400, 1700 and 2000s/mm2, respectively. Diagnostic performances were evaluated when Area-under-the-curve (AUC) > 95%. Results 15 of the 35 b-values pair surpassed this AUC threshold. The pair (50, 2000 s/mm2) provided the highest AUC (96%) with ADC cutoff 0.89 × 10–3 mm2/s, sensitivity 95.5%, specificity 93.2% and accuracy 94.4%. Conclusions The best b-value pair was b = 50, 2000 s/mm2.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.1016/j.clinimag.2017.09.004pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.22/14138
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherElsevierpt_PT
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S0899707117301705pt_PT
dc.subjectDiffusion weighted imagingpt_PT
dc.subjectDiffusion Magnetic Resonance Imagingpt_PT
dc.subjectProstatept_PT
dc.subjectProstatic Neoplasmspt_PT
dc.titleApparent diffusion coefficient in the analysis of prostate cancer: determination of optimal b-value pair to differentiate normal from malignant tissuept_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage95pt_PT
oaire.citation.startPage90pt_PT
oaire.citation.titleClinical Imagingpt_PT
oaire.citation.volume47pt_PT
person.familyNameAdubeiro
person.givenNameNuno
person.identifier.ciencia-id0119-2885-C797
person.identifier.orcid0000-0001-8657-3288
person.identifier.ridAAC-1663-2021
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication35d1aa21-3c2a-4af6-8346-efa61cd513fc
relation.isAuthorOfPublication.latestForDiscovery35d1aa21-3c2a-4af6-8346-efa61cd513fc

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ART_NunoAdubeiro_2018.pdf
Size:
331.67 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: