Repository logo
 
Publication

Electroanalytical study of the pesticide asulam

dc.contributor.authorNouws, Henri P. A.
dc.contributor.authorDelerue-Matos, Cristina
dc.contributor.authorLima, J. L. F. C.
dc.contributor.authorGarrido, E. Manuela
dc.contributor.authorVincke, Pieter
dc.contributor.authorMaes, Noel A.
dc.date.accessioned2013-11-27T15:06:08Z
dc.date.available2013-11-27T15:06:08Z
dc.date.issued2002
dc.description.abstractThe electrochemical behaviour of the herbicide Asulam was studied by cyclic and square wave voltammetry. Asulam may be irreversibly oxidised at a glassy carbon electrode. Maximum currents were obtained at pH=1.9 in aqueous electrolyte solution. Based on the electrochemical behaviour of Asulam, two analytical methodologies were developed for its determination in water samples, using square wave voltammetry (SWV) and flow injection analysis (FIA) coupled with an amperometric detector. Limits of detection of 7.1x10-6 mol L-1 and 1.2x10-8 mol L-1 for SWV and FIA respectively, were achieved. Repeatability was calculated by assessing the relative standard deviation (%) for 10 consecutive determinations of one sample. The found values were 2.1% for SWV and 5.0% for FIA. Validation of the results provided by SWV and FIA methodologies was performed by comparison with results from an HPLC-DAD technique. Good relative deviations were found (<5%). Recovery trials were performed to assess the accuracy of the results and the obtained values were between 84% and 107% for both methods.por
dc.identifier.doi10.1080/03067310290024111pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.22/2999
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherTaylor & Francispor
dc.relation.ispartofseriesInternational Journal of Environmental Analytical Chemistry; Vol. 82, Issue 2
dc.relation.publisherversionhttp://www.tandfonline.com/doi/abs/10.1080/03067310290024111#.UpYE7Ur6Q25por
dc.subjectAsulampor
dc.subjectHerbicidespor
dc.subjectOxidationpor
dc.subjectSquare wave voltammetrypor
dc.subjectFlow injection analysispor
dc.subjectAmperometric detectionpor
dc.titleElectroanalytical study of the pesticide asulampor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage76por
oaire.citation.startPage69por
oaire.citation.titleInternational Journal of Environmental Analytical Chemistrypor
oaire.citation.volume82por
person.familyNameDelerue-Matos
person.givenNameCristina
person.identifier.ciencia-id9A1A-43FB-5C27
person.identifier.orcid0000-0002-3924-776X
person.identifier.ridD-4990-2013
person.identifier.scopus-author-id6603741848
rcaap.rightsopenAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication09f6a7bd-2f15-42b0-adc5-04bd22210519
relation.isAuthorOfPublication.latestForDiscovery09f6a7bd-2f15-42b0-adc5-04bd22210519

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ART_HenriNouws_2002_GRAQ.pdf
Size:
112.04 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: