Repository logo
 
Publication

Is there a need for attenuation correction in the 99mTc-DMSA scans on pediatric patients?

dc.contributor.authorNogueira, Fábio
dc.contributor.authorLemos, Joana
dc.contributor.authorOliveira, Marta
dc.contributor.authorSilva, José A.
dc.contributor.authorSousa, Maria C.
dc.contributor.authorCunha, Lídia
dc.contributor.authorMetello, Luís F.
dc.date.accessioned2013-10-16T23:16:47Z
dc.date.available2013-10-16T23:16:47Z
dc.date.issued2010
dc.description.abstractIntroduction: The quantification of th e differential renal function in adults can be difficult due to many factors - on e of the se is the variances in kidney depth and the attenuation related with all the tissue s between the kidney and the camera. Some authors refer that t he lower attenuation i n p ediatric patients makes unnecessary the use of attenuation correction algorithms. This study will com pare the values of differential renal function obtained with and with out attenuation correction techniques . Material and Methods: Images from a group consisting of 15 individuals (aged 3 years +/ - 2) were used and two attenuation correction method s were applied – Tonnesen correction factors and the geometric mean method . The mean time of acquisition (time post 99m Tc - DMSA administration) was 3.5 hours +/ - 0.8h. Results: T he absence of any method of attenuation correction apparently seems to lead to consistent values that seem to correlate well with the ones obtained with the incorporation of methods of attenuation correction . The differences found between the values obtained with and without attenuation correction were not significant. Conclusion: T he decision of not doing any kind of attenuation correction method can apparently be justified by the minor differences verified on the relative kidney uptake values. Nevertheless, if it is recognized that there is a need for a really accurate value of the relative kidney uptake, then an attenuation correction method should be used.
dc.identifier.urihttp://hdl.handle.net/10400.22/2364
dc.language.isoengpor
dc.publisherInstituto Politécnico do Porto. Escola Superior de Tecnologia da Saúde do Porto
dc.titleIs there a need for attenuation correction in the 99mTc-DMSA scans on pediatric patients?por
dc.typelecture
dspace.entity.typePublication
oaire.citation.conferencePlaceInternationalpor
oaire.citation.titleI International Congress of Health Gaia-Portopor
person.familyNameLemos
person.familyNameCunha
person.givenNameJoana
person.givenNameLídia
person.identifier.ciencia-id3F11-3268-F06A
person.identifier.orcid0000-0002-5734-7166
person.identifier.orcid0000-0002-9260-8093
rcaap.rightsopenAccesspor
rcaap.typelecturepor
relation.isAuthorOfPublication04aa6dfe-65b2-4606-877b-3ebd15e78111
relation.isAuthorOfPublicationed51e8c5-a1c2-40e6-b976-57af77446e1b
relation.isAuthorOfPublication.latestForDiscovery04aa6dfe-65b2-4606-877b-3ebd15e78111

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
POS_FabioNogueira_2010.pdf
Size:
215.75 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: