Publication
A importância do OCT de segmento anterior na adaptação de lente escleral em pacientes com ceratocone: protocolo de consulta
dc.contributor.author | Dias, Libânia Matos Andrade Dias | |
dc.date.accessioned | 2023-03-27T13:38:28Z | |
dc.date.available | 2023-03-27T13:38:28Z | |
dc.date.issued | 2020 | |
dc.description | Trabalho realizado para a obtenção do Título de Especialista na área de Tecnologias de Diagnóstico e Terapêutica Ortóptica | pt_PT |
dc.description.abstract | O ceratocone é considerado a ectasia corneal mais comum, qu e se caracteriza por um adelgaçamento progress ivo da córnea com uma reduzida acuidade visual ( acompan hada por fotofobia, como resultado de um astigmatismo irregular Nesta situaç ão clínica recorre se frequentemente à adaptação de lentes de contacto Procu rou se assim, com a realização deste trabalho desenvolver um protocolo de adaptação de lente de contacto escleral (LCE) em pacientes com ceratocone, utilizando o OCT S egmento A nterior (OCT SA) SA), com o intuito de realizar de uma forma mais simples e segura a reabilitação visual destes pacientes Trata se de um estudo prospetivo e longitudinal , o qual inclui u 20 pacientes portadores de ceratocone. Todos os pacientes re aliza ram uma primeira consulta de observação oftalmológica antes da adaptação da lente ICD ™ 16.5. Após a adaptação foram realizadas quatro consultas: consulta d e ensino e consultas de seguimento aos 2, 6 e 12 meses . O OCT SA foi realizado em todas as co ns ultas, exce to na consulta de ensino A análise estatística foi efe tivada usando o programa StatView (SAS, Cary, NC) NC), considerando resultados com p<0.05 estatisticamente significativos Foram analisados 20 olhos com uma idade média 31.5 10.9 anos A AV média sem correção era de 0.03 0.06 a melhor AV corrigida era de 0.25 0.22 , tendo se verificado um aumento estatisticamente significativo após a colocação da LCE (p<0.0001), passando para 0.85 0.15 Não houve diferenças significativas entre a primeira e a última consulta. Analisando o vault da lente, verificou se que este sofre u um a diminuição estatisticamente significativa dos 6 meses para os 12 meses (p =0.0116 É possível con cluir que a existência de um protocolo de adaptação de LCE bem definido , incluindo a realização do OCT SA contribui para o sucesso do tratamento de pacientes com ceratocone . Este equipamento, não invasivo e de alta defini ção, permite encontrar , de forma mais segura , precisa e reprodutível, o equilíbrio perfeito entre uma córnea cónica e uma LCE | pt_PT |
dc.description.abstract | Keratoconus is considered the most common corneal ectasia, which is characterized by a progressive thinning of the cornea with reduced visual acuity ( VA ) accompanied by photophobia, as a result of irregular astigmatism. In this clinical situation, contact lenses are often used. W ith this work, we aimed to develop a scleral contact lens (SCL) adaptation protocol in patients with keratoconus, using the Segment Anterior OCT (SA OCT), in order to perform a visual rehabilitation of these patients in a simple an d safe way. This is a prospective and longitudinal study, which included 20 patients with keratoconus. All patients underwent a first ophthalmological consultation before fitting the ICD ™ 16.5 lens. After adaptation, four consultations were performed : teaching consultation and follow up consultations at 2, 6 and 12 months. SA OCT was performed in all consultations, except in the teaching consultation. The statistical analysis was carried out using the StatView program (SAS, Cary, NC), considering results with p <0.05 statistically significant. Twenty eyes were analyzed, with an average age of 31.5 10.9 years. The mean uncorrected VA was 0.03 0.06, the best corrected VA was 0.25 0.22, with a s tatistically significant increase after the placement of the SCL (p <0.0001), changing to 0.85 0.15. There were no significant differences between the first and the last consultation. Analyzing the lens vault, it was found a statisticall y significant decrease from 6 to 12 months (p = 0.0116). It is possible to conclude that the existence of a well defined SCL adaptation protocol, including the performance of SA OCT , contributes to the successful treatment of patients with keratocon us. This equipment, non invasive and with high definition, allows to find, in a safer, more accurate and reproducible way, the perfect balance between a conical cornea and a SCL | pt_PT |
dc.description.version | N/A | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.22/22608 | |
dc.language.iso | por | pt_PT |
dc.publisher | Instituto Politécnico do Porto. Escola Superior de Saúde | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | pt_PT |
dc.subject | Ortóptica | pt_PT |
dc.subject | Ceratocone | pt_PT |
dc.subject | Lente escleral | pt_PT |
dc.subject | Reduzida acuidade visual | pt_PT |
dc.title | A importância do OCT de segmento anterior na adaptação de lente escleral em pacientes com ceratocone: protocolo de consulta | pt_PT |
dc.type | report | |
dspace.entity.type | Publication | |
rcaap.rights | closedAccess | pt_PT |
rcaap.type | report | pt_PT |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Titulo de Especialista_LibaniaDias_Final.pdf
- Size:
- 630.21 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: