dc.description.abstractThe reduction of luvastatin (FLV) at a hanging mercury-drop electrode (HMDE) was studied by square-wave adsorptive-stripping voltammetry (SWAdSV). FLV can be accumulated and reduced at the electrode, with a maximum peak current intensity at a potential of approximately 1.26V vs. AgCl=Ag, in an aqueous electrolyte solution of pH 5.25. The method shows linearity between peak current intensity and FLV concentration between 1.0 10 8 and 2.7 10 6 mol L 1. Limits of detection (LOD) and quantification (LOQ) were found to be 9.9 10 9 mol L 1 and 3.3 10 8 mol L 1, respectively. Furthermore, FLV oxidation at a glassy carbon electrode surface was used for its hydrodynamic monitoring by amperometric detection in a flow-injection system. The amperometric signal was linear with FLV concentration over the range 1.0 10 6 to 1.0 10 5 mol L 1, with an LOD of 2.4 10 7 mol L 1 and an LOQ of 8.0 10 7 mol L 1. A sample rate of 50 injections per hour was achieved. Both methods were validated and showed to be precise and accurate, being satisfactorily applied to the determination of FLV in a commercial pharmaceutical.por
dc.identifier.doi10.1080/00032710802421889pt_PT
dc.identifier.issn0003-2719
dc.identifier.issn1532-236X
dc.identifier.urihttp://hdl.handle.net/10400.22/2951
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherTaylor & Francispor
dc.relation.ispartofseriesAnalytical Letters; Vol. 41, Issue 15
dc.relation.publisherversionhttp://www.tandfonline.com/doi/abs/10.1080/00032710802421889#.UooaQH9qyZQpor
dc.subjectAdsorptive-stripping voltammetrypor
dc.subjectAmperometric detectionpor
dc.subjectFlow injection analysispor
dc.subjectFluvastatinpor
dc.subjectHanging mercury drop electrodepor
dc.subjectPharmaceutical analysispor
dc.titleDirect electroanalytical determination of fluvastatin in a pharmaceutical dosage form: batch and flow analysispor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage2804por
oaire.citation.startPage2794por
oaire.citation.titleAnalytical Letterspor
person.familyNameDelerue-Matos
person.givenNameCristina
person.identifier.ciencia-id9A1A-43FB-5C27
person.identifier.orcid0000-0002-3924-776X
person.identifier.ridD-4990-2013
person.identifier.scopus-author-id6603741848
rcaap.rightsopenAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication09f6a7bd-2f15-42b0-adc5-04bd22210519
relation.isAuthorOfPublication.latestForDiscovery09f6a7bd-2f15-42b0-adc5-04bd22210519

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ART_MartaNeves_2008_GRAQ.pdf
Size:
356.64 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: