Repository logo
 
Publication

Automated fluence map optimization based on fuzzy inference systems

dc.contributor.authorDias, Joana
dc.contributor.authorRocha, Humberto
dc.contributor.authorVentura, Tiago
dc.contributor.authorBC Ferreira
dc.contributor.authorLopes, Maria do Carmo
dc.date.accessioned2019-06-07T12:31:47Z
dc.date.available2019-06-07T12:31:47Z
dc.date.issued2016
dc.description.abstractThe planning of an intensity modulated radiation therapy treatment requires the optimization of the fluence intensities. The fluence map optimization (FMO) is many times based on a nonlinear continuous programming problem, being necessary for the planner to define a priori weights and/or lower bounds that are iteratively changed within a trial-and-error procedure until an acceptable plan is reached. In this work, the authors describe an alternative approach for FMO that releases the human planner from trial-and-error procedures, contributing for the automation of the planning process.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.1118/1.4941007pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.22/13919
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherAmerican Association of Physicists in Medicinept_PT
dc.relationCENTRO-07-ST24-FEDER- 002003pt_PT
dc.relation.publisherversionhttps://aapm.onlinelibrary.wiley.com/doi/abs/10.1118/1.4941007pt_PT
dc.subjectRadiotherapy treatment planningpt_PT
dc.subjectIMRTpt_PT
dc.subjectOrgans at Riskpt_PT
dc.subjectRadiotherapy Dosagept_PT
dc.subjectRadiotherapy Planning, Computer-Assistedpt_PT
dc.subjectTomography, X-Ray Computedpt_PT
dc.subjectFuzzy Logicpt_PT
dc.subjectFluence Map Optimizationpt_PT
dc.titleAutomated fluence map optimization based on fuzzy inference systemspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/5876/UID%2FMulti%2F00308%2F2013/PT
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/COMPETE/PTDC%2FEIA-CCO%2F121450%2F2010/PT
oaire.citation.endPage1095pt_PT
oaire.citation.issue3pt_PT
oaire.citation.startPage1083pt_PT
oaire.citation.titleMedical Physicspt_PT
oaire.citation.volume43pt_PT
oaire.fundingStream5876
oaire.fundingStreamCOMPETE
person.familyNameCosta Ferreira
person.givenNameBrigida
person.identifier1167997
person.identifier.ciencia-idA61B-E07B-84B3
person.identifier.orcid0000-0001-7988-7545
person.identifier.scopus-author-id14050253300
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.nameFundação para a Ciência e a Tecnologia
project.funder.nameFundação para a Ciência e a Tecnologia
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationeac8b2c3-0ef3-48f5-a3c7-8ca796a098ae
relation.isAuthorOfPublication.latestForDiscoveryeac8b2c3-0ef3-48f5-a3c7-8ca796a098ae
relation.isProjectOfPublicationc62bc2c1-fa52-4719-ac2f-51bbd780c4c9
relation.isProjectOfPublication5d657eed-3fe3-4b0f-92d0-0bc8759bfcd8
relation.isProjectOfPublication.latestForDiscoveryc62bc2c1-fa52-4719-ac2f-51bbd780c4c9

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ART_BrigidaFerreira_2016.pdf
Size:
418.42 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: