Estudo de uma instalação de climatização adiabática

dc.contributor.advisorNeto, Maria Paula Moreira de Carvalho Amorim
dc.contributor.advisorGuedes, Anabela
dc.contributor.advisorSerrano, Pedro
dc.contributor.authorDuarte, Ana Cristina da Silva
dc.date.accessioned2014-07-02T09:31:14Z
dc.date.available2014-07-02T09:31:14Z
dc.date.issued2013
dc.description.abstractEsta dissertação teve como objetivo o estudo de uma central de climatização adiabática, que tem como finalidade controlar a temperatura e a humidade de um salão com equipamentos de torcedura e de bobinagem, pertencente à Continental - ITA. Foi realizado um levantamento de dados relativamente à temperatura e humidade interior e exterior do referido salão. Verificou-se que estes parâmetros não estavam dentro dos valores ótimos desejados, 26 ± 1˚C e 50 ± 5%, e por isso foi necessário estimar as necessidades nominais de arrefecimento. Este valor foi determinado a partir do Regulamento das Características de Comportamento Térmico dos Edifícios (RCCTE), obtendo-se o valor de 79 kWh/m2.˚C. No sentido de avaliar se as centrais de climatização instaladas no salão em estudo satisfaziam estas necessidades, calcularam-se as suas capacidades de arrefecimento obtendo-se um valor máximo de 64 kWh/m2.˚C. Paralelamente a este estudo, foi calculada a eficiência de humidificação para cada central nos meses de março e setembro. Os valores obtidos foram oscilantes obtendo-se um valor máximo de 100% em setembro. Este fato deve-se à temperatura exterior neste mês ser mais alta e, por consequência, a eficiência de humidificação da central é maior, pois a quantidade de água que o ar pode conter na sua composição é também mais elevada. Com o objetivo de colmatar a diferença entre as necessidades nominais de arrefecimento e a capacidade de arrefecimento das centrais, foram analisadas algumas soluções que, a serem implementadas, poderiam ajudar na poupança energética. Uma dessas soluções era a substituição do sistema atual de humidificação por um sistema mais eficiente de alta pressão. Com o estudo económico deste investimento obteve-se um período de retorno de dois anos. Foram ainda apresentados mais dois investimentos onde foi alterado o sistema de controlo automático existente, obtendo-se para um, dois anos de período de retorno e para o outro três anos e meio.por
dc.description.abstractThis work aimed to study a HVAC adiabatic central that controls the temperature and humidity of a room with equipment of twisting and winding, belonging to Continental-ITA. A data survey on the temperature and humidity inside and outside of that room was performed. It has been established that these parameters were not within the desired optimal values, 26 ± 1 ˚ C and 50 ± 5%, therefore it was necessary to estimate the cooling nominal needs. This value was calculated using the Regulation Characteristics of Thermal Performance of Buildings (RCCTE). A value of 79 kWh/(m2˚C) was obtained. In order to assess if the air conditioning system that was installed satisfies these needs, its cooling capacity was determined at a maximum level of 64 kWh/(m2˚C). In parallel, it was evaluated the humidification for each central in the months of March and September. The values obtained were very oscillating with a maximum of 100% in September. This is due to a higher outdoor temperature during the period of this month and consequently the humidification efficiency is higher, because the amount of water that the air can hold in its composition is also higher. Aiming to bridge the gap between the nominal cooling needs and the cooling capacity of cooling units, some solutions were analyzed so that they could be implemented to help with energy conservation. One solution was to replace the current system of humidification for a more efficient system of high pressure. With the economic study of this investment we have obtained a return period of two years. Also presented were two additional investments in which the existent automatic control system was changed, the first investment will have a two years payback period and the second three and half years.por
dc.identifier.tid201813041
dc.identifier.urihttp://hdl.handle.net/10400.22/4616
dc.language.isoporpor
dc.peerreviewedyespor
dc.publisherInstituto Politécnico do Porto. Instituto Superior de Engenharia do Porto.por
dc.subjectClimatizaçãopor
dc.subjectClimatização adiabáticapor
dc.subjectHumidificaçãopor
dc.subjectRCCTEpor
dc.subjectAir cooling systemspor
dc.subjectEvaporative coolingpor
dc.titleEstudo de uma instalação de climatização adiabáticapor
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspor
rcaap.typemasterThesispor

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
DM_AnaDuarte_2013_MEQ.pdf
Tamanho:
7.69 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: