Logo do repositório
 
A carregar...
Miniatura
Publicação

Electroanalytical study of the antidepressant sertraline

Utilize este identificador para referenciar este registo.
Nome:Descrição:Tamanho:Formato: 
ART_HNouws_2005_GRAQ.pdf215.48 KBAdobe PDF Ver/Abrir

Orientador(es)

Resumo(s)

Aflowinjection squarewave cathodic stripping voltammetric method has been developed for the determination of sertraline in a pharmaceutical preparation. The method shows linearity between peak current intensity and sertraline concentration for the interval between 0.20×10−6 and 1.20×10−6 mol L−1. Limits of detection and quantification were found to be 1.5×10−7 and 5.0×10−7 mol L−1, respectively. Up to 70 samples per hour can be analysed with a good precision (R.S.D. = 2.5%). The proposed method was successfully applied to the determination of sertraline in a commercial product. In the voltammetric determination of sertraline in flow, a high sample rate is obtained at reduced costs, opening the possibility to compete with the chromatographic methods generally used for this analysis.

Descrição

Palavras-chave

Flow injection Hanging mercury drop electrode Adsorptive stripping voltammetry Sertraline SSRI

Contexto Educativo

Citação

Projetos de investigação

Unidades organizacionais

Fascículo

Editora

Elsevier

Licença CC

Métricas Alternativas