Repository logo
 
Publication

An easy procedure for calibrating data acquisition systems using interleaving

dc.contributor.authorClemĂȘncio, Filomena
dc.contributor.authorLoureiro, CustĂłdio F. M.
dc.contributor.authorCorreia, Carlos M. B. A.
dc.date.accessioned2024-10-03T12:12:06Z
dc.date.available2024-10-03T12:12:06Z
dc.date.issued2007-08
dc.description.abstractInterleaving data acquisition channels is a well-known and interesting technique to achieve higher acquisition rates. However, to obtain the expected benefits, a careful look at the interleaving technique and to mismatches that can lead to unwanted harmonic distortion and noise is essential. In this paper we discuss the methods used to interleave existing high-speed, 250 MSPS 8-bit acquisition channels, and the results obtained. The methods presented allowed a good relative channel calibration in amplitude (amplitude mismatch under 0.1 lsb) and in time (time mismatch between acquisition channels in the ps range, under the specified maximum jitter for the ADC used). A dynamic, by software, amplitude level signal-dependent adjustment procedure is also suggested for signals with rich frequency content that can substantially improve the quality of the acquired signal when using interleaved channels. The techniques presented provide good results even in the presence of noise.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationClemencio, F. M. C., Loureiro, C. F. M., & Correia, C. M. B. A. (2007). An Easy Procedure for Calibrating Data Acquisition Systems Using Interleaving. IEEE Transactions on Nuclear Science, 54(4), 1227–1231. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/TNS.2007.903166pt_PT
dc.identifier.doi10.1109/TNS.2007.903166pt_PT
dc.identifier.eissn1558-1578
dc.identifier.issn0018-9499
dc.identifier.urihttp://hdl.handle.net/10400.22/26193
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherIEEE Xplorept_PT
dc.relation.publisherversionhttps://ieeexplore.ieee.org/document/4291751pt_PT
dc.subjectData acquisitionpt_PT
dc.subjectInterleaved systemspt_PT
dc.titleAn easy procedure for calibrating data acquisition systems using interleavingpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage1231pt_PT
oaire.citation.startPage1227pt_PT
oaire.citation.titleIEEE Transactions on Nuclear Sciencept_PT
oaire.citation.volume54 (4)pt_PT
person.familyNameCosta ClemĂȘncio
person.givenNameFilomena Maria
person.identifier.ciencia-id7410-2E4A-3BD6
person.identifier.orcid0000-0003-0453-1151
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationccab7b9f-9d63-4134-b551-97bb103d8255
relation.isAuthorOfPublication.latestForDiscoveryccab7b9f-9d63-4134-b551-97bb103d8255

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ART_Filomena ClemĂȘncio 1.pdf
Size:
1.14 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: