Variability of noise levels in a portuguese neonatal intensive care unit

dc.contributor.authorCarvalhais, Carlos
dc.contributor.authorRodrigues, Célia
dc.contributor.authorXavier, Ana
dc.contributor.authorSilva, Manuela V.
dc.contributor.authorSantos, Joana
dc.date.accessioned2023-04-03T13:41:24Z
dc.date.available2023-04-03T13:41:24Z
dc.date.issued2021-04-21
dc.description.abstractThe neonatal intensive care units accommodates patients who are confined to their environment, being exposed to several environmental factors, such as noise. There exist a few official recommendations regarding noise levels within the hospital environment. The World Health Organization (WHO) proposes that the average background noise in hospitals should not exceed 35 dB LAeq for areas where patients are treated or observed and other organizations such the United States Environmental Protection Agency (45 dB(A) daytime / 35 dB(A) night) and the American Academy of Paediatrics, through the Committee on Environmental Health (45 dB(A)). The aim of this study was to investigate the intensity and pattern of noise levels such as variability and their sources within a Portuguese NICU. The study was carried out in a NICU located in the North of Portugal. The measurements were carried out continuously over 24 hours, next the workstation located at the centre of the NICU. Measurements were performed using a sound level meter class 1 (Brüel&Kjær, model 2250) which was verified with an acoustic calibrator class 1 (Brüel&Kjær, model 4231). The results showed that noise levels were excessive in the NICU, exceeding the international recommendations. The average levels were 55.3±5.4 dB(A) for LAeq with the levels ranging between 41.3 dB(A) (recorded at 5:09 a.m.) to 71.60 dB(A) (recorded at 12:58 p.m.). The highest LCpeak level was 104.4 dB (C) (recorded at 6:15 a.m.). For the other acoustic parameters, it was found 84.8 dB(A) for Lmax and 39.6 dB(A) for Lmin. The occurrence of high average noise levels in combination with the variability in noise levels and the frequency of peak noises may contribute to detrimental effects both for premature infants and health care professionals. Average noise levels exceeded those recommended by the WHO. The primary sources of noise were identified as staff conversations and alarms. Further research into strategies to reduce noise, and evaluation of interventions, is required to enhance by one side the therapeutic environment and for other the healthy and safe workplace.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationCarlos Carvalhais, Célia Rodrigues, Ana Xavier, Manuela V. Silva, & Joana Santos. (2021). Variability of noise levels in a portuguese neonatal intensive care unit. 2021: IFEH 4th World Academic Conference on Environmental Health - Book of Abstracts.pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.22/22670
dc.language.isoengpt_PT
dc.relation.publisherversionhttps://ojs.vvg.hr/index.php/IFEH/indexpt_PT
dc.subjectNICUpt_PT
dc.subjectNoisept_PT
dc.subjectPremature infantspt_PT
dc.subjectHealthcare staffpt_PT
dc.titleVariability of noise levels in a portuguese neonatal intensive care unitpt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.title2021: IFEH 4th World Academic Conference on Environmental Health - Book of Abstractspt_PT
person.familyNameAlberto Alves Carvalhais
person.familyNameVieira da Silva
person.familyNameSantos
person.givenNameCarlos
person.givenNameManuela
person.givenNameJoana
person.identifier2545573
person.identifier.ciencia-idF31F-77A1-CAE6
person.identifier.ciencia-id8C1D-7FC0-8460
person.identifier.ciencia-id0B12-58BF-915C
person.identifier.orcid0000-0002-4352-4555
person.identifier.orcid0000-0003-1256-990X
person.identifier.orcid0000-0002-2777-3244
person.identifier.scopus-author-id57449894700
person.identifier.scopus-author-id56746987300
rcaap.rightsopenAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublication58164790-a719-4356-98db-6165011f14c1
relation.isAuthorOfPublicationfb3cca0a-0dc9-4702-83ae-fbca6b94e1da
relation.isAuthorOfPublicationa4cdd7ab-26fd-4c58-911b-617fd5d85c39
relation.isAuthorOfPublication.latestForDiscovery58164790-a719-4356-98db-6165011f14c1

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
POSTER3_CarlosCarvalhais.pdf
Size:
2.25 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: