Repository logo
 
Publication

Image upsampling algorithms applied on Nuclear Medicine: comparision of hqnx and nxSaI algorithms families with two interpolation algorithms - nearest neighbour and bicubic interpolation

dc.contributor.authorNogueira, Fábio
dc.contributor.authorMatias, Mariana
dc.contributor.authorSoares, Sofia
dc.contributor.authorCunha, Lídia
dc.contributor.authorMetello, Luís F.
dc.date.accessioned2015-05-27T14:05:30Z
dc.date.available2015-05-27T14:05:30Z
dc.date.issued2010-10-09
dc.description.abstractIntroduction: Image resizing is a normal feature incorporated into the Nuclear Medicine digital imaging. Upsampling is done by manufacturers to adequately fit more the acquired images on the display screen and it is applied when there is a need to increase - or decrease - the total number of pixels. This paper pretends to compare the “hqnx” and the “nxSaI” magnification algorithms with two interpolation algorithms – “nearest neighbor” and “bicubic interpolation” – in the image upsampling operations. Material and Methods: Three distinct Nuclear Medicine images were enlarged 2 and 4 times with the different digital image resizing algorithms (nearest neighbor, bicubic interpolation nxSaI and hqnx). To evaluate the pixel’s changes between the different output images, 3D whole image plot profiles and surface plots were used as an addition to the visual approach in the 4x upsampled images. Results: In the 2x enlarged images the visual differences were not so noteworthy. Although, it was clearly noticed that bicubic interpolation presented the best results. In the 4x enlarged images the differences were significant, with the bicubic interpolated images presenting the best results. Hqnx resized images presented better quality than 4xSaI and nearest neighbor interpolated images, however, its intense “halo effect” affects greatly the definition and boundaries of the image contents. Conclusion: The hqnx and the nxSaI algorithms were designed for images with clear edges and so its use in Nuclear Medicine images is obviously inadequate. Bicubic interpolation seems, from the algorithms studied, the most suitable and its each day wider applications seem to show it, being assumed as a multi-image type efficient algorithm.por
dc.identifier.urihttp://hdl.handle.net/10400.22/6127
dc.language.isoengpor
dc.titleImage upsampling algorithms applied on Nuclear Medicine: comparision of hqnx and nxSaI algorithms families with two interpolation algorithms - nearest neighbour and bicubic interpolationpor
dc.typelecture
dspace.entity.typePublication
oaire.citation.titleVienna 2010 - Annual Congress of the European Association of Nuclear Medicinepor
person.familyNameCunha
person.givenNameLídia
person.identifier.orcid0000-0002-9260-8093
rcaap.rightsopenAccesspor
rcaap.typelecturepor
relation.isAuthorOfPublicationed51e8c5-a1c2-40e6-b976-57af77446e1b
relation.isAuthorOfPublication.latestForDiscoveryed51e8c5-a1c2-40e6-b976-57af77446e1b

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Image upsampling algorithms applied on Nuclear Medicine - comparision of hqnx and nxSaI algorithms families with two interpolation algorithms - nearest neighbour and bicubic interpolation.pdf
Size:
228.71 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: