Response to: Does reliability benefit from superior visualization of epileptiform discharges on inferior temporal electrodes?

dc.contributor.authorBatista, Carla
dc.contributor.authorSoares, Joana Isabel
dc.contributor.authorCoelho, Paulo
dc.contributor.authorFerreira, Simão
dc.contributor.authorRosenzweig, Ivana
dc.contributor.authorBorges, Daniel Filipe
dc.contributor.authorBorges, Daniel Filipe
dc.contributor.authorFerreira, Simão
dc.date.accessioned2025-12-18T12:31:06Z
dc.date.available2025-12-18T12:31:06Z
dc.date.issued2025-11-21
dc.description.abstractWe thank Dr. Kleine for his thoughtful letter regarding our study and for highlighting both the anatomical rationale and the recognized clinical relevance of inferior-temporal electrodes. We welcome the opportunity to clarify specific numerical points and to provide the inter-reviewer agreement data he requested. Our study was intentionally designed as a prospective, blinded, within-subject technical validation comparing the IFCN-recommended 25-electrode 19-channel 10–20 International System (10–20 IS) in consecutive(IFCN-25) array with the conventional 19-channel 10–20 International System (10–20 IS) in consecutive adult EEGs. Importantly, it was not framed as a diagnostic or superiority trial: no external gold standard was applied, and both montages were treated methodologically as equivalent acquisition systems. The primary endpoint was patient-level detection of any abnormality (IEDs or focal slow activity) under blinded real-world conditions. In this reply, we address exclusively the point raised by Dr. Kleine concerning inter-reviewer agreement for temporal-lobe IEDs, providing the 2 × 2 tables and κ values requested. These analyses represent a clear subset of the broader dataset already published and are provided here for transparency.por
dc.identifier.citationBatista, C., Soares, J. I., Coelho, P., Ferreira, S., Rosenzweig, I., & Borges, D. F. (2025, novembro 21). Response to: Does reliability benefit from superior visualization of epileptiform discharges on inferior temporal electrodes? [Carta ao editor].
dc.identifier.doi10.1002/epd2.70146
dc.identifier.eissn1950-6946
dc.identifier.issn1294-9361
dc.identifier.urihttp://hdl.handle.net/10400.22/31261
dc.language.isoeng
dc.peerreviewedyes
dc.publisherWiley
dc.relation.hasversionhttps://onlinelibrary.wiley.com/doi/10.1002/epd2.70146
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleResponse to: Does reliability benefit from superior visualization of epileptiform discharges on inferior temporal electrodes?eng
dc.typeletter to the editor
dspace.entity.typePublication
oaire.citation.endPage2
oaire.citation.startPage1
oaire.citation.titleEpileptic Disorders
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
person.familyNameBorges
person.familyNameFerreira
person.givenNameDaniel Filipe
person.givenNameSimão
person.identifier3235598
person.identifier2680796
person.identifier.ciencia-id0217-87F9-58DF
person.identifier.ciencia-idB11E-1BD3-5F34
person.identifier.orcid0000-0003-0189-7908
person.identifier.orcid0000-0001-8233-2217
person.identifier.ridJVO-1831-2024
person.identifier.scopus-author-id57912703700
person.identifier.scopus-author-id57359736400
relation.isAuthorOfPublicationf67e814a-8ad9-4440-820a-deaccea87bb8
relation.isAuthorOfPublication0bd5b0fc-6849-4f36-b751-87e7f4c81eff
relation.isAuthorOfPublication.latestForDiscoveryf67e814a-8ad9-4440-820a-deaccea87bb8

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Carta ao editor_Daniel Borges.pdf
Size:
2.91 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.03 KB
Format:
Item-specific license agreed upon to submission
Description: