Publication
Response to: Does reliability benefit from superior visualization of epileptiform discharges on inferior temporal electrodes?
| dc.contributor.author | Batista, Carla | |
| dc.contributor.author | Soares, Joana Isabel | |
| dc.contributor.author | Coelho, Paulo | |
| dc.contributor.author | Ferreira, Simão | |
| dc.contributor.author | Rosenzweig, Ivana | |
| dc.contributor.author | Borges, Daniel Filipe | |
| dc.contributor.author | Borges, Daniel Filipe | |
| dc.contributor.author | Ferreira, Simão | |
| dc.date.accessioned | 2025-12-18T12:31:06Z | |
| dc.date.available | 2025-12-18T12:31:06Z | |
| dc.date.issued | 2025-11-21 | |
| dc.description.abstract | We thank Dr. Kleine for his thoughtful letter regarding our study and for highlighting both the anatomical rationale and the recognized clinical relevance of inferior-temporal electrodes. We welcome the opportunity to clarify specific numerical points and to provide the inter-reviewer agreement data he requested. Our study was intentionally designed as a prospective, blinded, within-subject technical validation comparing the IFCN-recommended 25-electrode 19-channel 10–20 International System (10–20 IS) in consecutive(IFCN-25) array with the conventional 19-channel 10–20 International System (10–20 IS) in consecutive adult EEGs. Importantly, it was not framed as a diagnostic or superiority trial: no external gold standard was applied, and both montages were treated methodologically as equivalent acquisition systems. The primary endpoint was patient-level detection of any abnormality (IEDs or focal slow activity) under blinded real-world conditions. In this reply, we address exclusively the point raised by Dr. Kleine concerning inter-reviewer agreement for temporal-lobe IEDs, providing the 2 × 2 tables and κ values requested. These analyses represent a clear subset of the broader dataset already published and are provided here for transparency. | por |
| dc.identifier.citation | Batista, C., Soares, J. I., Coelho, P., Ferreira, S., Rosenzweig, I., & Borges, D. F. (2025, novembro 21). Response to: Does reliability benefit from superior visualization of epileptiform discharges on inferior temporal electrodes? [Carta ao editor]. | |
| dc.identifier.doi | 10.1002/epd2.70146 | |
| dc.identifier.eissn | 1950-6946 | |
| dc.identifier.issn | 1294-9361 | |
| dc.identifier.uri | http://hdl.handle.net/10400.22/31261 | |
| dc.language.iso | eng | |
| dc.peerreviewed | yes | |
| dc.publisher | Wiley | |
| dc.relation.hasversion | https://onlinelibrary.wiley.com/doi/10.1002/epd2.70146 | |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
| dc.title | Response to: Does reliability benefit from superior visualization of epileptiform discharges on inferior temporal electrodes? | eng |
| dc.type | letter to the editor | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 2 | |
| oaire.citation.startPage | 1 | |
| oaire.citation.title | Epileptic Disorders | |
| oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| person.familyName | Borges | |
| person.familyName | Ferreira | |
| person.givenName | Daniel Filipe | |
| person.givenName | Simão | |
| person.identifier | 3235598 | |
| person.identifier | 2680796 | |
| person.identifier.ciencia-id | 0217-87F9-58DF | |
| person.identifier.ciencia-id | B11E-1BD3-5F34 | |
| person.identifier.orcid | 0000-0003-0189-7908 | |
| person.identifier.orcid | 0000-0001-8233-2217 | |
| person.identifier.rid | JVO-1831-2024 | |
| person.identifier.scopus-author-id | 57912703700 | |
| person.identifier.scopus-author-id | 57359736400 | |
| relation.isAuthorOfPublication | f67e814a-8ad9-4440-820a-deaccea87bb8 | |
| relation.isAuthorOfPublication | 0bd5b0fc-6849-4f36-b751-87e7f4c81eff | |
| relation.isAuthorOfPublication.latestForDiscovery | f67e814a-8ad9-4440-820a-deaccea87bb8 |
