Publication
Novel and simple electrochemical biosensor monitoring attomolar levels of miRNA-155 in breast cancer
dc.contributor.author | Cardoso, Ana Rita | |
dc.contributor.author | Moreira, Felismina | |
dc.contributor.author | Fernandes, Rúben | |
dc.contributor.author | Sales, Goreti | |
dc.date.accessioned | 2017-07-13T11:52:39Z | |
dc.date.embargo | 2117 | |
dc.date.issued | 2016 | |
dc.description.abstract | This work, describes for the first time, a simple biosensing design to yield an ultrasensitive electro-chemical biosensor for a cancer biomarker detection, miRNA-155, with linear response down to the attomolar range. MiRNA-155 was selected for being overexpressed in breast cancer. The biosensor was assembled in two stages: (1) the immobilization of the anti-miRNA-155 that was thiol modified on an Au-screen printed electrode (Au-SPE), followed by (2) blocking the areas of non-specific binding with mercaptosuccinic acid. Atomic force microscopy (AFM) and electrochemical tech-niques including cyclic voltammetry (CV), impedance spectroscopy (EIS) and square wave voltammetry (SWV) confirmed the surface modification of these devices and their ability to hybridize successfully and stably with miRNA-155. The final biosensor provided a sensitive detection of miRNA-155 from 10 aM to 1.0 nM with a low detection limit (LOD) of 5.7 aM in real human serum samples. Good results were obtained in terms of selectivity towards breast cancer antigen CA-15.3 and bovine serum albumin (BSA). Raw fluid extracts from cell-lines of melanoma did not affect the biosensor response (no significant change of the blank), while raw extracts from breast cancer yielded a positive signal against miRNA-155. This simple and sensitive strategy is a promising alternative for simultaneous quantitative analysis of multiple miRNA in physiological fluids for biomedical research and point-of-care (POC) diagnosis. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.doi | 10.1016/j.bios.2016.02.035 | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.22/10049 | |
dc.language.iso | eng | pt_PT |
dc.publisher | Elsevier | pt_PT |
dc.relation.ispartofseries | Biosensors and Bioelectronics;Vol. 80 | |
dc.relation.publisherversion | http://www.sciencedirect.com/science/article/pii/S0956566316301427 | pt_PT |
dc.subject | Breast cancer | pt_PT |
dc.subject | Anti-miRNA-155 | pt_PT |
dc.subject | miRNA-155 | pt_PT |
dc.subject | Biosensors | pt_PT |
dc.subject | Eletrochemistry | pt_PT |
dc.title | Novel and simple electrochemical biosensor monitoring attomolar levels of miRNA-155 in breast cancer | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.title | Biosensors and Bioelectronics | pt_PT |
person.familyName | Cardoso | |
person.familyName | Moreira | |
person.familyName | Fernandes | |
person.familyName | Ferreira Sales | |
person.givenName | Ana Rita | |
person.givenName | Felismina | |
person.givenName | Rúben | |
person.givenName | Maria Goreti | |
person.identifier | 1589429 | |
person.identifier | 635792 | |
person.identifier | 826970 | |
person.identifier.ciencia-id | F717-044B-1E8D | |
person.identifier.ciencia-id | C917-6A46-A270 | |
person.identifier.ciencia-id | 0D1F-4090-E82A | |
person.identifier.ciencia-id | E31F-1630-42BB | |
person.identifier.orcid | 0000-0002-8641-0865 | |
person.identifier.orcid | 0000-0003-4237-8952 | |
person.identifier.orcid | 0000-0001-8933-3984 | |
person.identifier.orcid | 0000-0001-9936-7336 | |
person.identifier.rid | K-9199-2013 | |
person.identifier.scopus-author-id | 57125522400 | |
person.identifier.scopus-author-id | 23486193000 | |
person.identifier.scopus-author-id | 57640135700 | |
person.identifier.scopus-author-id | 7005174717 | |
rcaap.rights | closedAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | eeb95820-2553-4ad8-8d44-501ffd2c76ff | |
relation.isAuthorOfPublication | 9c13153d-a73a-49ff-b7f6-c9733bc6725e | |
relation.isAuthorOfPublication | 9e6c397c-62d8-4a40-8ec7-ad05ae0ebcc4 | |
relation.isAuthorOfPublication | b6d3a2d0-608a-4a92-834b-8d7b29069fef | |
relation.isAuthorOfPublication.latestForDiscovery | 9e6c397c-62d8-4a40-8ec7-ad05ae0ebcc4 |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- ART_FelisminaMoreira_BioMark_2016.pdf
- Size:
- 1.26 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: