Repository logo
 
Publication

An easy procedure for calibrating data systems using interleaving

dc.contributor.authorClemĂȘncio, Filomena
dc.contributor.authorLoureiro, CustĂłdio F. M.
dc.contributor.authorCorreia, Carlos M. B. A.
dc.date.accessioned2024-10-03T12:23:53Z
dc.date.available2024-10-03T12:23:53Z
dc.date.issued2005-10
dc.description.abstractInterleaving data acquisition channels is a well-known and interesting technique to achieve higher acquisition rates. However, to obtain the expected benefits, a careful look at the interleaving technique and to mismatches that can lead to unwanted harmonic distortion and noise is essential. In this paper we discuss the methods used to interleave existing high-speed, 250 MSPS 8-bit acquisition channels, and the results obtained. The methods presented allowed a good channel calibration in amplitude (amplitude mismatch under 0.1 lsb) and in time (time mismatch between acquisition channels in the ps range, under the specified maximum jitter for the ADC used). A dynamic, by software, amplitude level signal-dependent adjustment procedure is also suggested for signals with reach frequency content that can substantially improve the quality of the acquired signal when using interleaved channels. The techniques presented provide good results even in the presence of noise.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationClemencio, F. M. C., Loureiro, C. F. M., & Correia, C. M. B. A. (2005). An easy procedure for calibrating data systems using interleaving. IEEE Nuclear Science Symposium Conference Record, 2005, 2, 680–684. https://doi.org/10.1109/NSSMIC.2005.1596350pt_PT
dc.identifier.doi10.1109/NSSMIC.2005.1596350pt_PT
dc.identifier.isbn0-7803-9221-3
dc.identifier.issn1082-3654
dc.identifier.urihttp://hdl.handle.net/10400.22/26195
dc.language.isoengpt_PT
dc.publisherIEEE Xplorept_PT
dc.relation.publisherversionhttps://ieeexplore.ieee.org/document/1596350pt_PT
dc.subjectUnwanted noisept_PT
dc.subjectCareful lookpt_PT
dc.subjectAcquisition channelspt_PT
dc.subjectTiming mismatchpt_PT
dc.subjectInterpolationpt_PT
dc.subjectFrequent testingpt_PT
dc.subjectDiscrete fourier transformpt_PT
dc.subjectSpectral componentspt_PT
dc.subjectPeak searchpt_PT
dc.subjectSinusoidal frequencypt_PT
dc.subjectAmplitudept_PT
dc.subjectCorrectionpt_PT
dc.titleAn easy procedure for calibrating data systems using interleavingpt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlaceFajardo, PR, USApt_PT
oaire.citation.endPage684pt_PT
oaire.citation.startPage680pt_PT
oaire.citation.titleIEEE Nuclear Science Symposium Conference Recordpt_PT
person.familyNameCosta ClemĂȘncio
person.givenNameFilomena Maria
person.identifier.ciencia-id7410-2E4A-3BD6
person.identifier.orcid0000-0003-0453-1151
rcaap.rightsrestrictedAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublicationccab7b9f-9d63-4134-b551-97bb103d8255
relation.isAuthorOfPublication.latestForDiscoveryccab7b9f-9d63-4134-b551-97bb103d8255

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
COM_Filomena ClemĂȘncio 1.pdf
Size:
900.19 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: