Publication
Disposable electrochemical immunosensor for analysis of cystatin C, a CKD biomarker
dc.contributor.author | LOPES, Paula | |
dc.contributor.author | Costa Rama, Estefanía | |
dc.contributor.author | Beirão, Idalina | |
dc.contributor.author | Nouws, Henri | |
dc.contributor.author | Santos-Silva, Alice | |
dc.contributor.author | Delerue-Matos, Cristina | |
dc.date.accessioned | 2020-06-25T14:27:36Z | |
dc.date.available | 2020-06-25T14:27:36Z | |
dc.date.issued | 2019-08-15 | |
dc.description.abstract | Specific monitoring of cystatin C (CysC) levels in biological fluids is critical for diagnosis, treatment and mechanistic understanding of a spectrum of diseases, particularly chronic kidney disease (CKD). Despite evidences that CysC correlates with the high risk and/or progression of CKD, its use in clinical practice is still scarce. In this context, we report the development of a simple and sensitive immunosensor for the detection of CysC. The biosensor combines the technology of cost-effective screen-printed electrodes with the high specificity of a sandwich immunoassay. Optimized conditions showed that the sensor operates in a linear range between 10 and 100 ng mL-1, with a detection limit and a sensitivity of 6.0 ng mL-1 and 6.4 ± 0.3 μA ng mL-1 cm-2, respectively. Moreover, the sensor provided precise results (RSD ≤ 6.2%) and the quantification of CysC in CKD serum samples revealed to be in agreement with the values obtained by a particle-enhanced nephelometric immunoassay. In this light, the proposed immunosensor qualifies for clinical application, constituting a step forward in the development of fast, sensitive and cost-effective diagnostic tools that can improve the current medical care settings of CKD patients. | pt_PT |
dc.description.sponsorship | This work was supported by European Union through projects Norte-01-0145-FEDER-000024 and Norte-01-0145-FEDER-000011, co-funded by FEDER in the scope of CCDR-N and NORTE2020 Partnership Agreement. This work also received financial support from the European Union (FEDER funds through COMPETE) and National Funds (FCT, Fundação para a Ciência e a Tecnologia) through project UID/QUI/50006/2013. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.doi | 10.1016/j.talanta.2019.04.006 | pt_PT |
dc.identifier.issn | 0039-9140 | |
dc.identifier.uri | http://hdl.handle.net/10400.22/16012 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.relation.publisherversion | https://www.sciencedirect.com/science/article/abs/pii/S0039914019303959?via%3Dihub | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | pt_PT |
dc.subject | Electrochemical immunosensor | pt_PT |
dc.subject | Biomarker | pt_PT |
dc.subject | Cystatin C | pt_PT |
dc.subject | Chronic kidney disease | pt_PT |
dc.subject | Screen-printed electrodes | pt_PT |
dc.subject | Gold nanoparticles | pt_PT |
dc.title | Disposable electrochemical immunosensor for analysis of cystatin C, a CKD biomarker | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.awardURI | info:eu-repo/grantAgreement/FCT/5876/UID%2FQUI%2F50006%2F2013/PT | |
oaire.citation.endPage | 216 | pt_PT |
oaire.citation.startPage | 211 | pt_PT |
oaire.citation.title | Talanta | pt_PT |
oaire.citation.volume | 201 | pt_PT |
oaire.fundingStream | 5876 | |
person.familyName | LOPES | |
person.familyName | Costa Rama | |
person.familyName | Nouws | |
person.familyName | Delerue-Matos | |
person.givenName | Paula | |
person.givenName | Estefanía | |
person.givenName | Hendrikus | |
person.givenName | Cristina | |
person.identifier | 1046746 | |
person.identifier.ciencia-id | 7C18-36BB-82B6 | |
person.identifier.ciencia-id | 3614-E403-0136 | |
person.identifier.ciencia-id | 9B1A-9CED-6EE3 | |
person.identifier.ciencia-id | 9A1A-43FB-5C27 | |
person.identifier.orcid | 0000-0003-4034-7722 | |
person.identifier.orcid | 0000-0002-5357-9269 | |
person.identifier.orcid | 0000-0002-1472-8866 | |
person.identifier.orcid | 0000-0002-3924-776X | |
person.identifier.rid | J-5815-2018 | |
person.identifier.rid | D-5249-2013 | |
person.identifier.rid | D-4990-2013 | |
person.identifier.scopus-author-id | 55808813100 | |
person.identifier.scopus-author-id | 36703129800 | |
person.identifier.scopus-author-id | 7801450247 | |
person.identifier.scopus-author-id | 6603741848 | |
project.funder.identifier | http://doi.org/10.13039/501100001871 | |
project.funder.name | Fundação para a Ciência e a Tecnologia | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | 761c689d-3b68-40d9-9385-5f1cbf459a23 | |
relation.isAuthorOfPublication | c5426470-28f7-4ec9-98d5-58910259931c | |
relation.isAuthorOfPublication | 2c48191f-fb0f-44a5-9435-88912f2a4bbc | |
relation.isAuthorOfPublication | 09f6a7bd-2f15-42b0-adc5-04bd22210519 | |
relation.isAuthorOfPublication.latestForDiscovery | 09f6a7bd-2f15-42b0-adc5-04bd22210519 | |
relation.isProjectOfPublication | 5c06a623-3499-408c-aef9-0a1f68cb1d02 | |
relation.isProjectOfPublication.latestForDiscovery | 5c06a623-3499-408c-aef9-0a1f68cb1d02 |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- ART_GRAQ_DELERUE_2019_7.pdf
- Size:
- 662.61 KB
- Format:
- Adobe Portable Document Format