Repository logo
 
Publication

Desenvolvimento de um sensor ótico para a deteção do biomarcador de cancro MMP7

datacite.subject.fosCiências Médicas
datacite.subject.fosEngenharia e Tecnologia
datacite.subject.sdg09:Indústria, Inovação e Infraestruturas
dc.contributor.advisorMarques, Maria Arcelina
dc.contributor.authorOliveira, Pedro Miguel Carneiro
dc.date.accessioned2025-04-03T12:52:51Z
dc.date.available2025-04-03T12:52:51Z
dc.date.issued2025-02-26
dc.description.abstractA doença oncológica tem mostrado uma tendência crescente nas últimas décadas, tornando-se um problema de saúde pública. A falta de meios práticos e clinicamente confiáveis para a monitorização do cancro representa um desafio no acompanhamento da doença em pacientes que sofrem ou já sofreram desta condição. Para preencher essa lacuna, há a necessidade de se desenvolverem novas estratégias sensoras para a deteção de biomarcadores associados a esta doença. Um dos biomarcadores selecionado para o desenvolvimento deste trabalho, foi a metaloproteinase de matriz 7 (MMP7, do inglês matrix metalloproteinase 7), conhecida por ser expressa no cancro de pâncreas. Neste contexto, desenvolveu-se um sensor biomimético denominado MIP@PQs, que consiste na conjugação de polímeros molecularmente impressos (MIPs, do inglês, molecularly imprinted polymers), com pontos quânticos (PQs). A construção do sensor utilizou PQs de telureto de cádmio com emissão alaranjada, funcionalizados com ácido 3-mercaptopropiónico (CdTe@MPA), que foram conjugados aos MIPs e utilizados na deteção do biomarcador MMP7 em soro humano liofilizado diluído a 1% em PBS (do inglês, phosphate buffer saline). Os MIP@PQs apresentaram uma ampla faixa de deteção abaixo do valor de corte clínico para MMP7, boa praticidade e seletividade em amostras de soro diluídas, o que indica o seu potencial para várias aplicações biológicas. Considerando o desempenho promissor do sensor biomimético em solução, planeia-se fazer a sua deposição em suporte sólido e avaliar a resposta analítica ao biomarcador MMP7, constituindo uma potencial linha de investigação para a continuação deste estudo.por
dc.description.abstractOncological disease has shown a rising trend over the past decades, becoming a major public health concern. The lack of practical and clinically reliable methods for cancer monitoring presents a challenge in tracking the disease in patients currently affected or who have had this condition. To address this gap, it is necessary to develop new sensing strategies for the detection of biomarkers associated with cancer. One of the biomarkers selected for this work was matrix metalloproteinase 7 (MMP7), known for its expression in pancreatic cancer. In this context, a biomimetic sensor was developed based on molecularly imprinted polymers (MIPs) combined with quantum dots, referred to as MIP@PQs. The sensor construction utilized orange-emitting cadmium telluride quantum dots functionalized with 3-mercaptopropionic acid (CdTe@MPA), which were conjugated with MIPs and used in detecting the biomarker MMP7 in lyiohilized human serum 1% diluted in phosphate buffer saline, PBS. The MIP@PQs exhibited a broad detection range below the clinical cutoff for MMP7, demonstrating excellent practicality and selectivity in diluted serum samples, indicating its potential for various biological applications Given the promising performance of the biomimetic sensor in solution, the next step involves its deposition onto a solid support to evaluate its analytical response to the MMP7 biomarker. This approach opens a potential avenue for future research to continue this study.eng
dc.description.sponsorshipFinanciado
dc.identifier.tid203931092
dc.identifier.urihttp://hdl.handle.net/10400.22/29923
dc.language.isopor
dc.rights.uriN/A
dc.subjectMolecularly imprinted polymers
dc.subjectquantum dots
dc.subjectbiomimetic optic sensor
dc.subjectMIP@PQs
dc.subjectpancreatic cancer
dc.subjectMMP7 biomarker
dc.subjectPolímeros de impressão molecular
dc.subjectPontos quânticos
dc.subjectSensor ótico biomimético
dc.subjectMIP@POs
dc.subjectCancro do Pâncreas
dc.subjectBiomarcador MMP7
dc.titleDesenvolvimento de um sensor ótico para a deteção do biomarcador de cancro MMP7
dc.title.alternativeDevelopment of an optical sensor for detection of the cancer biomarker MMP7eng
dc.typemaster thesis
dspace.entity.typePublication
thesis.degree.nameMestrado em Engenharia Biomédica

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Tese_5679_v2_Confi1ano_financi_Pedro Oliveira.pdf
Size:
5.9 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.03 KB
Format:
Item-specific license agreed upon to submission
Description: