Repository logo
 
Publication

Performance analysis of a VLC system applied to a hospital environment for IoT- based smart patient monitoring

dc.contributor.authorFernández, Benjamín
dc.contributor.authorJátiva, Pablo Palacios
dc.contributor.authorAzurdia Meza, Cesar A.
dc.contributor.authorBoettcher, Nicolás
dc.contributor.authorZabala Blanco, David
dc.contributor.authorGutiérrez Gaitán, Miguel
dc.contributor.authorSoto, Ismael
dc.date.accessioned2024-09-13T10:36:59Z
dc.date.available2024-09-13T10:36:59Z
dc.date.issued2024
dc.description.abstractThis article discusses the deployment of effective communication networks for smart IoT-based smart patient monitoring in medical facilities, advocating for the adoption of Visible Light Communication (VLC) technology. Initially, the physical scenario is analyzed, taking into account factors such as line-of-sight (LOS) and nonline-of-sight (NLOS) channel components. Furthermore, a transmitter is designed to offer a substitute in the event of potential disruptions due to patient motion or loss of line-of-sight elements. The performance of the proposed system is verified under certain performance metrics, such as the Channel Impulse Response (CIR) and the Cumulative Distribution Function (CDF), with respect to power measurements at different points. The results highlight the effects that NLOS rays have on the received data and the received power. Therefore, this study serves as a step towards the development of more sophisticated systems for patient monitoring using enabling technologies such as VLC.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationFernández, B., Játiva, P.P., Azurdia Meza, C.,A., Boettcher, N., Zabala Blanco, D., Gutiérrez Gaitán, M., & Soto, I. (July 17-19, 2024). Performance analysis of a VLC system applied to a hospital environment for IoT- based smart patient monitoring [Conference session]. CSNDSP 2024 - 14th International Symposium on Communication Systems, Networks and Digital Signal Processing, Rome, Italypt_PT
dc.identifier.urihttp://hdl.handle.net/10400.22/25999
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.subjectE-HEALTHpt_PT
dc.subjectInternet of Thingspt_PT
dc.subjectOptical channelspt_PT
dc.subjectSmart patient monitoringpt_PT
dc.subjectVisible Light Communicationpt_PT
dc.titlePerformance analysis of a VLC system applied to a hospital environment for IoT- based smart patient monitoringpt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlaceRome, Italypt_PT
oaire.citation.titleCSNDSP 2024 - 14th International Symposium on Communication Systems, Networks and Digital Signal Processingpt_PT
person.familyNameGutiérrez Gaitán
person.givenNameMiguel
person.identifier.orcid0000-0002-3307-8731
person.identifier.scopus-author-id57192172325
rcaap.rightsopenAccess
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublication3512370f-381d-42ec-95e1-6ddd459c8169
relation.isAuthorOfPublication.latestForDiscovery3512370f-381d-42ec-95e1-6ddd459c8169

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
CISTER-TR-240505.pdf
Size:
612.97 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: