| datacite.subject.fos | Engenharia e Tecnologia::Engenharia do Ambiente | |
| datacite.subject.sdg | 07:Energias Renováveis e Acessíveis | |
| datacite.subject.sdg | 09:Indústria, Inovação e Infraestruturas | |
| dc.contributor.advisor | Nogueira, Teresa Alexandra Ferreira Mourão Pinto | |
| dc.contributor.author | MOREIRA, MARIANA NEVES | |
| dc.date.accessioned | 2026-09-23T12:08:15Z | |
| dc.date.available | 2026-09-23T12:08:15Z | |
| dc.date.issued | 2026-07-08 | |
| dc.description.abstract | A presente dissertação teve como objetivo analisar e otimizar a produção e a utilização da energia fotovoltaica nas instalações da Amorim Cork Solutions, com enfoque na avaliação do desempenho real do sistema, na identificação de falhas e perdas, e na análise de oportunidades de melhoria técnica e operacional. O trabalho incidiu sobre as quatro unidades de negócio da empresa — Pólo 1, Pólo 2, Pólo 3 e Pólo 4 — e envolveu a caracterização das instalações fotovoltaicas, a análise dos perfis de produção, consumo e excedentes, bem como a comparação entre os dados obtidos através da plataforma e+Monitor e das plataformas oficiais dos inversores. Esta abordagem permitiu identificar divergências de monitorização, situações anómalas nos registos de produção e limitações relevantes para a avaliação do desempenho do sistema. Foram propostas três medidas de otimização técnica, todas com payback inferior a um ano. O contador de consumo dedicado ao PT3, para controlo da limitação de excedentes, gerou uma poupança de 170,7 MWh e 14 856 euros anuais, com investimento de 3 500 euros e payback de 0,24 anos. Os pontos de água para limpeza dos módulos aumentaram a produção cerca de 14% nas zonas intervencionadas, com poupança de 172 MWh e 15 482 euros, investimento de 4 650 euros e payback de 0,30 anos. A instalação de climatização da sala 1 de inversores do PT2.1 com poupança de 17 629 euros, investimento de 16 990 euros e payback de 0,9 anos. Paralelamente, foi analisado o enquadramento das comunidades de energia renovável e a sua aplicabilidade às unidades de negócio da ACS, tendo em vista o reforço do autoconsumo e uma gestão mais eficiente da energia produzida. Os resultados reforçam a importância da qualidade dos dados, da deteção atempada de falhas e da articulação entre análise técnica e decisão operacional para maximizar o aproveitamento fotovoltaico em contexto industrial, evidenciando ainda o potencial das comunidades de energia e de futuras soluções de monitorização inteligente. | por |
| dc.description.abstract | The objective of this dissertation was to analyze and optimize the production and use of photovoltaic energy at Amorim Cork Solutions’ facilities, with a focus on evaluating the system’s actual performance, identifying faults and losses, and analyzing opportunities for technical and operational improvements. The study focused on the company’s four business units—Polo 1, Polo 2, Polo 3, and Polo 4—and involved characterizing the photovoltaic installations, analyzing production, consumption, and surplus profiles, as well as comparing data obtained through the eMonitor platform with data from the inverters’ official platforms. This approach made it possible to identify monitoring discrepancies, anomalous situations in production records, and limitations relevant to the evaluation of system performance. Three technical optimization measures were proposed, all with a payback period of less than one year. The consumption meter dedicated to PT3, designed to excess production limits, generated annual savings of 170.7 MWh and 14.856 euros, with an investment of 3,500 euros and a payback period of 0.24 years. The water stations for cleaning the modules increased production by approximately 14% in the areas where they were installed, resulting in savings of 172 MWh and 15,482 euros, an investment of 4,650 euros, and a payback period of 0.30 years. The installation of an air conditioning in Room 1 of the PT2.1 inverter room resulting in savings of 17,629 euros, an investment of 16,990 euros, and a payback period of 0.9 years. At the same time, the framework for renewable energy communities and its applicability to ACS’s business units were analyzed, with a view to strengthening selfconsumption and ensuring more efficient management of the energy produced. The results underscore the importance of data quality, timely fault detection, and the integration of technical analysis with operational decision-making to maximize photovoltaic utilization in an industrial setting, while also highlighting the potential of energy communities and future smart monitoring solutions. | eng |
| dc.identifier.tid | 204361893 | |
| dc.identifier.uri | http://hdl.handle.net/10400.22/32849 | |
| dc.language.iso | por | |
| dc.rights.uri | N/A | |
| dc.subject | Monitoring | |
| dc.subject | Maintenance | |
| dc.subject | Efficiency | |
| dc.subject | Self-consumption | |
| dc.subject | Renewable energy communities | |
| dc.subject | Monitorização | |
| dc.subject | Manutenção | |
| dc.subject | Eficiência | |
| dc.subject | Autoconsumo | |
| dc.subject | Comunidades energia renovável | |
| dc.title | Otimização da produção e utilização do fotovoltaico | por |
| dc.title.alternative | Optimization of photovoltaic production and use | eng |
| dc.type | master thesis | |
| dspace.entity.type | Publication | |
| thesis.degree.name | Mestrado em Energias Sustentáveis |