Publication
The Effect of Demand Response in the Minimum Available Reserve of Energy Management
dc.contributor.author | Soares, João | |
dc.contributor.author | Borges, Nuno | |
dc.contributor.author | Fotouhi, Ali | |
dc.contributor.author | Vale, Zita | |
dc.date.accessioned | 2017-07-07T15:04:30Z | |
dc.date.available | 2017-07-07T15:04:30Z | |
dc.date.issued | 2016 | |
dc.description.abstract | This paper presents a multi-objective energy scheduling for the daily operation of a Smart Grid (SG) considering maximization of the minimum available reserve in addition to the cost minimization, to take into account the reliability requirements of critical and vulnerable loads. A Virtual Power Player (VPP) manages the day-ahead energy resource scheduling in the smart grid, considering Distributed Generation (DG) and Vehicle-To-Grid (V2G), while maintaining a highly reliable power for the critical loads. This work considers high penetration of critical loads, e.g. industrial processes that require high power quality, high reliability and few interruptions. A mathematical formulation is described and a deterministic technique based on Mixed-Integer Linear Programming (MILP) is used to solve the multi-objective problem. The effect of some customers with DR in this context is analyzed to assess the benefits in the energy scheduling problem. A case study using a 180-bus Portuguese distribution network with 90 load points, several DG units and a large fleet of Electric Vehicles (EVs) with V2G is used to illustrate the performance of the proposed method. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.doi | 10.1109/PESGM.2016.7741853 | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.22/10008 | |
dc.language.iso | eng | pt_PT |
dc.publisher | Institute of Electrical and Electronics Engineers | pt_PT |
dc.relation.ispartofseries | PESGM;2016 | |
dc.relation.publisherversion | http://ieeexplore.ieee.org/document/7741853/ | pt_PT |
dc.subject | Electric Vehicles | pt_PT |
dc.subject | Multi-objective optimization | pt_PT |
dc.subject | Pareto front | pt_PT |
dc.subject | Mixed-Integer Linear Programming | pt_PT |
dc.subject | Smart Grid | pt_PT |
dc.title | The Effect of Demand Response in the Minimum Available Reserve of Energy Management | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.title | IEEE POWER AND ENERGY SOCIETY GENERAL MEETING | pt_PT |
person.familyName | Soares | |
person.familyName | Vale | |
person.givenName | João | |
person.givenName | Zita | |
person.identifier | 1043580 | |
person.identifier | 632184 | |
person.identifier.ciencia-id | 1612-8EA8-D0E8 | |
person.identifier.ciencia-id | 721B-B0EB-7141 | |
person.identifier.orcid | 0000-0002-4172-4502 | |
person.identifier.orcid | 0000-0002-4560-9544 | |
person.identifier.rid | A-5824-2012 | |
person.identifier.scopus-author-id | 35436109600 | |
person.identifier.scopus-author-id | 7004115775 | |
rcaap.rights | closedAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | 9ece308b-6d79-4cec-af91-f2278dcc47eb | |
relation.isAuthorOfPublication | ff1df02d-0c0f-4db1-bf7d-78863a99420b | |
relation.isAuthorOfPublication.latestForDiscovery | 9ece308b-6d79-4cec-af91-f2278dcc47eb |