Repository logo
 
Publication

Wood Connections Under Fire Conditions Protected with Gypsum Plasterboard Types A and F

dc.contributor.authorFonseca, Elza M M
dc.contributor.authorLeite, Pedro A. S.
dc.contributor.authorSilva, Lino
dc.date.accessioned2020-01-02T14:40:29Z
dc.date.embargo2120
dc.date.issued2020-11
dc.description.abstractThe wood behavior varies with temperature, which has a negative effect, be-ing verified by progressive properties degradation. After fire exposure, it is possible to measure the wood char layer and the remaining resistant cross-section area. Based on numerical models and analytical equations, it is pos-sible to study the protection level of wood connections, during fire exposure, and evaluate wood and steel dowels temperature fields in conjunction. The main objective of this work is to verify the fire resistance of unprotected (W-W-W) wood connections and compare the results with protected connections using gypsum plasterboard. According Eurocode 5, part 1-2 the connections could be protected by the addition of wood paneling, wood-based panels or gypsum plasterboard type A, H or F. To obtain conclusions according the application of different type of gypsum plasterboard in the designed W-W-W connections in different densities material, numerical models were building to verify the level of protection in fire action. Design methods require the use of analytical methodologies and computational modelling to predict the fire exposure and the components capacity to resist to this action. Results of the temperature field in the studied connections under fire will be presented, with the measured char layer in unprotected members and comparing the protected efficiency with different types of gypsum plasterboard.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.1007/978-3-030-36240-9_7pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.22/15189
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherSpringer Nature Switzerland AG 2020pt_PT
dc.relation.publisherversionhttps://link.springer.com/chapter/10.1007%2F978-3-030-36240-9_7pt_PT
dc.subjectW-W-W connectionpt_PT
dc.subjectFirept_PT
dc.subjectProtected connectionpt_PT
dc.subjectCharring ratept_PT
dc.titleWood Connections Under Fire Conditions Protected with Gypsum Plasterboard Types A and Fpt_PT
dc.typebook part
dspace.entity.typePublication
oaire.citation.endPage106pt_PT
oaire.citation.startPage93pt_PT
oaire.citation.titleAdvances in Fire Safety Engineeringpt_PT
oaire.citation.volume1pt_PT
person.familyNameFonseca
person.givenNameElza M M
person.identifierR-000-4MB
person.identifier.ciencia-idEB17-92E5-8374
person.identifier.orcid0000-0003-1854-6514
person.identifier.ridD-4604-2011
person.identifier.scopus-author-id7102526169
rcaap.rightsrestrictedAccesspt_PT
rcaap.typebookPartpt_PT
relation.isAuthorOfPublication9c47bcbc-5c0c-4553-8a0e-b0b1e4ea287f
relation.isAuthorOfPublication.latestForDiscovery9c47bcbc-5c0c-4553-8a0e-b0b1e4ea287f

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
CAPL_CIDEM_ElzaFonseca_2020.pdf
Size:
2.18 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: