Repository logo
 
Publication

MIP-graphene-modified glassy carbon electrode for the determination of trimethoprim

dc.contributor.authorSilva, Hélder
dc.contributor.authorPacheco, João G.
dc.contributor.authorMagalhães, Júlia Maria Coelho Santos
dc.contributor.authorViswanathan, Subramanian
dc.contributor.authorDelerue-Matos, Cristina
dc.date.accessioned2014-12-22T14:48:59Z
dc.date.available2014-12-22T14:48:59Z
dc.date.issued2014-02-15
dc.description.abstractA novel sensitive electrochemical sensor was developed by electropolymerization of pyrrole(PY)and molecularly imprinted polymer (MIP)which was synthesized onto a glassy carbon electrode (GCE) in aqueous solution using cyclic voltammetry in the presence of Trimethoprim (TMP) as template molecules. Furthermore,a previous electrode modification was performed by deposition of a suspension of graphene on the electrode's surface. The performance of the imprinted and non-imprinted (NIP) films was evaluated by impedance spectroscopy (EIS) and cyclic voltammetry (CV) of a ferric solution. The molecularly imprinted film exhibited a high selectivity and sensitivity toward TMP. The sensor presented a linear range, between peak current intensity and logarithm of TMP concentration between 1.0x10-6 and 1.0x10-4 M. The results were accurate (with recoveries higher than 94%), precise (with standard deviations less than 5%) and the detection limit was 1.3x10-7 M. The new sensor is selective, simple to construct and easy to operate. The MIP sensor was successfully applied to quantify TMP in urinesamples.por
dc.identifier.doi10.1016/j.bios.2013.08.035
dc.identifier.urihttp://hdl.handle.net/10400.22/5270
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.relation.ispartofseriesBiosensors and Bioelectronics;Vol. 52
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S0956566313005848por
dc.subjectTrimethoprimpor
dc.subjectElectrochemical sensorpor
dc.subjectMolecularly Imprinting Polymer (MIP)por
dc.subjectGraphenepor
dc.subjectPyrrolepor
dc.titleMIP-graphene-modified glassy carbon electrode for the determination of trimethoprimpor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage61por
oaire.citation.startPage56por
oaire.citation.titleBiosensors and Bioelectronicspor
oaire.citation.volume52por
person.familyNameDelerue-Matos
person.givenNameCristina
person.identifier.ciencia-id9A1A-43FB-5C27
person.identifier.orcid0000-0002-3924-776X
person.identifier.ridD-4990-2013
person.identifier.scopus-author-id6603741848
rcaap.rightsclosedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication09f6a7bd-2f15-42b0-adc5-04bd22210519
relation.isAuthorOfPublication.latestForDiscovery09f6a7bd-2f15-42b0-adc5-04bd22210519

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ART_5_GRAQ_2014.pdf
Size:
724.32 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: