Repository logo
 
Publication

Sarcosine oxidase composite screen-printed electrode for sarcosine determination in biological samples

dc.contributor.authorRebelo, Tânia S. C. R.
dc.contributor.authorPereira, Carlos M.
dc.contributor.authorSales, M. Goreti F.
dc.contributor.authorNoronha, João P. C.
dc.contributor.authorCosta-Rodrigues, João
dc.contributor.authorSilva, Fernando
dc.contributor.authorFernandes, M.H.
dc.date.accessioned2015-10-15T14:35:29Z
dc.date.available2015-10-15T14:35:29Z
dc.date.issued2014
dc.description.abstractAs the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.pt_PT
dc.identifier.doi10.1016/j.aca.2014.08.005
dc.identifier.urihttp://hdl.handle.net/10400.22/6698
dc.language.isoengpt_PT
dc.publisherElsevierpt_PT
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S0003267014009520pt_PT
dc.subjectSarcosinept_PT
dc.subjectSarcosine oxidasept_PT
dc.subjectElectrochemical biosensorpt_PT
dc.subjectScreen-printed electrodespt_PT
dc.subjectUrinept_PT
dc.titleSarcosine oxidase composite screen-printed electrode for sarcosine determination in biological samplespt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage32pt_PT
oaire.citation.startPage26pt_PT
oaire.citation.titleAnalytica Chimica Actapt_PT
oaire.citation.volume850pt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ART_TaniaRebelo_2014.pdf
Size:
1.69 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: