Repository logo
 
Publication

Fast screening procedure for antibiotics in wastewaters by direct HPLC-DAD analysis

dc.contributor.authorTeixeira, Salomé
dc.contributor.authorDelerue-Matos, Cristina
dc.contributor.authorAlves, Arminda
dc.contributor.authorSantos, Lúcia
dc.date.accessioned2013-11-21T15:28:51Z
dc.date.available2013-11-21T15:28:51Z
dc.date.issued2008
dc.description.abstractGrowing concern about the contamination of wastewaters by antibiotics demands fast but sensitive analytical methodologies, for the screening of a large number of samples. The purpose of this work was to develop a simple methodology, using direct injection of the samples, by HPLC with diode array detection (DAD), for a multiresidue analysis of five antibiotics of different classes. Wastewater from an urban water treatment plant was selected as a model to study possible coelution of interfering compounds. The linearity interval ranged from 40 to 400 µg/L for amoxicillin (Amox), metronidazole (Metro), cefazolin (Cefa), and chloramphenicol (Chloram) and from 20 to 200 µg/L for sulfamethoxazole (Sulfa), with LODs lower than 14 µg/L. Repeatability, expressed by the CV of six repeated injections, ranged from 1 to 8%, while the intermediate precision varied between 2 and 11%. The recovery ranged from 90 to 109%. This method enables the fast screening of a large number of samples, with an expanded uncertainty in the 1–22% range. The advantage of the proposed method is to significantly reduce the number of samples to be analyzed by more complex methods.por
dc.identifier.doi10.1002/jssc.200800229pt_PT
dc.identifier.urihttp://recipp.ipp.pt/handle/10400.22/2896
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherWILEY-VCH Verlag GmbH & Co.por
dc.relation.publisherversionhttps://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/jssc.200800229por
dc.subjectAntibioticspor
dc.subjectHPLC-DADpor
dc.subjectScreeningpor
dc.subjectUncertaintypor
dc.subjectWastewaterpor
dc.titleFast screening procedure for antibiotics in wastewaters by direct HPLC-DAD analysispor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage2931por
oaire.citation.issue31por
oaire.citation.startPage2924por
oaire.citation.titleJss-Journalpor
person.familyNameDelerue-Matos
person.givenNameCristina
person.identifier.ciencia-id9A1A-43FB-5C27
person.identifier.orcid0000-0002-3924-776X
person.identifier.ridD-4990-2013
person.identifier.scopus-author-id6603741848
rcaap.rightsopenAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication09f6a7bd-2f15-42b0-adc5-04bd22210519
relation.isAuthorOfPublication.latestForDiscovery09f6a7bd-2f15-42b0-adc5-04bd22210519

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ART_SalomeTeixeira_2008_GRAQ.pdf
Size:
95.84 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: