Logo do repositório
 
Publicação

Electrochemical Sensing Platforms for HER2-ECD Breast Cancer Biomarker Detection

dc.contributor.authorFreitas, Maria
dc.contributor.authorNouws, Henri P. A.
dc.contributor.authorDelerue-Matos, Cristina
dc.date.accessioned2021-01-05T16:40:06Z
dc.date.available2021-01-05T16:40:06Z
dc.date.issued2019
dc.description.abstractScreening and early diagnosis are crucial to increase the success of cancer patients’ treatments and improve the survival rate. To contribute to this success, distinct electrochemical immunosensing platforms were developed for the analysis of the ExtraCellular Domain of the Human Epidermal growth factor Receptor 2 (HER2‐ECD) through sandwich assays on nanomaterial‐modified screen‐printed carbon electrodes (SPCEs). The most promising platforms showed to be SPCEs modified with (i) gold nanoparticles (AuNPs) and (ii) multiwalled carbon nanotubes combined with AuNPs. The antibody‐antigen interaction was detected using a secondary antibody labelled with alkaline phosphatase and 3‐indoxyl phosphate and silver ions as the enzymatic substrate. The electrochemical signal of the enzymatically generated metallic silver was recorded by linear sweep voltammetry. Under the optimized conditions, linear calibration plots were obtained between 7.5 and 50 ng/mL and the total assay time was 2 h 20 min, achieving LODs of 0.16 ng/mL (SPCE‐MWCNT/AuNP) and 8.5 ng/mL (SPCE‐AuNP), which are well below the established cut‐off value of 15 ng/mL for this cancer biomarker.pt_PT
dc.description.sponsorshipMaria Freitas is grateful to FCT‐Fundação para a Ciência e a Tecnologia for her PhD grant (SFRH/BD/111942/2015), financed by POPH‐QREN‐Tipologia 4.1‐Formação Avançada, subsidized by Fundo Social Europeu and Ministério da Ciência, Tecnologia e Ensino Superior. This work received financial support from the European Union (FEDER funds through COMPETE) and National Funds (FCT) through project UID/QUI/50006/2013.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.1002/elan.201800537pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.22/16660
dc.language.isoengpt_PT
dc.publisherWileypt_PT
dc.relation.publisherversionhttps://onlinelibrary.wiley.com/doi/full/10.1002/elan.201800537pt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectElectrochemical Sensing Platformspt_PT
dc.subjectBreast Cancerpt_PT
dc.subjectBiomarker Detectionpt_PT
dc.titleElectrochemical Sensing Platforms for HER2-ECD Breast Cancer Biomarker Detectionpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/5876/UID%2FQUI%2F50006%2F2013/PT
oaire.citation.endPage128pt_PT
oaire.citation.issue1pt_PT
oaire.citation.startPage121pt_PT
oaire.citation.titleElectroanalysispt_PT
oaire.citation.volume31pt_PT
oaire.fundingStream5876
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.nameFundação para a Ciência e a Tecnologia
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isProjectOfPublication5c06a623-3499-408c-aef9-0a1f68cb1d02
relation.isProjectOfPublication.latestForDiscovery5c06a623-3499-408c-aef9-0a1f68cb1d02

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
ART_DELERUE_2019_29.pdf
Tamanho:
518.46 KB
Formato:
Adobe Portable Document Format