Repository logo
 
Publication

Rapid automated method for on-site determination of sulfadiazine in fish farming: a stainless steel veterinary syringe coated with a selective membrane of PVC serving as a potentiometric detector in a flow-injection-analysis system

dc.contributor.authorAlmeida, Sofia A. A.
dc.contributor.authorAmorim, L. R.
dc.contributor.authorHeitor, A. H.
dc.contributor.authorMontenegro, M.C.B.S.M.
dc.contributor.authorBarbosa, J.
dc.contributor.authorSá, L. C.
dc.date.accessioned2015-10-19T15:47:12Z
dc.date.available2015-10-19T15:47:12Z
dc.date.issued2011
dc.description.abstractSulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.pt_PT
dc.identifier.doi10.1007/s00216-011-5441-1
dc.identifier.urihttp://hdl.handle.net/10400.22/6758
dc.language.isoengpt_PT
dc.publisherOriginal Paperpt_PT
dc.relation.publisherversionhttp://link.springer.com/article/10.1007%2Fs00216-011-5441-1pt_PT
dc.subjectSulfadiazinept_PT
dc.subjectChemical sensor.pt_PT
dc.subjectAquaculturept_PT
dc.subjectFlow-injection analysispt_PT
dc.subjectPotentiometrypt_PT
dc.titleRapid automated method for on-site determination of sulfadiazine in fish farming: a stainless steel veterinary syringe coated with a selective membrane of PVC serving as a potentiometric detector in a flow-injection-analysis systempt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage3365pt_PT
oaire.citation.startPage3355pt_PT
oaire.citation.titleAnalytical and Bioanalytical Chemistrypt_PT
oaire.citation.volume401pt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ART_GoretiSales4_2011.pdf
Size:
450.26 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: