Repository logo
 
Publication

Diffusion characteristics of ethylene glycol in skeletal muscle

dc.contributor.authorOliveira, Luís
dc.contributor.authorCarvalho, Maria
dc.contributor.authorNogueira, Elisabete
dc.contributor.authorTuchin, Valery
dc.date.accessioned2019-03-19T16:12:29Z
dc.date.available2019-03-19T16:12:29Z
dc.date.issued2015-05-01
dc.description.abstractPart of the optical clearing study in biological tissues concerns the determination of the diffusion characteristics of water and optical clearing agents in the subject tissue. Such information is sufficient to characterize the time dependence of the optical clearing mechanisms—tissue dehydration and refractive index (RI) matching. We have used a simple method based on collimated optical transmittance measurements made from muscle samples under treatment with aqueous solutions containing different concentrations of ethylene glycol (EG), to determine the diffusion time values of water and EG in skeletal muscle. By representing the estimated mean diffusion time values from each treatment as a function of agent concentration in solution, we could identify the real diffusion times for water and agent. These values allowed for the calculation of the correspondent diffusion coefficients for those fluids. With these results, we have demonstrated that the dehydration mechanism is the one that dominates optical clearing in the first minute of treatment, while the RI matching takes over the optical clearing operations after that and remains for a longer time of treatment up to about 10 min, as we could see for EG and thin tissue samples of 0.5 mm.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.1117/1.JBO.20.5.051019pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.22/13056
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherSociety of Photo-optical Instrumentation Engineerspt_PT
dc.relation.ispartofseriesJBO;Vol. 20, nº 5
dc.subjectOptical clearingpt_PT
dc.subjectAgent diffusionpt_PT
dc.subjectDiffusion coefficientpt_PT
dc.subjectCollimated transmittancept_PT
dc.subjectTissue dehydrationpt_PT
dc.subjectRefractive index matchingpt_PT
dc.titleDiffusion characteristics of ethylene glycol in skeletal musclept_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage051019-10pt_PT
oaire.citation.issue5pt_PT
oaire.citation.startPage051019-1pt_PT
oaire.citation.titleJournal of Biomedical Opticspt_PT
oaire.citation.volume20pt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ART_CIETI_LMO_JBO2015.pdf
Size:
2.8 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: