Repository logo
 
Loading...
Project Logo
Research Project

(Bio)sensors for assessment of contaminants of emerging concern in fishery commodities

Authors

Publications

The simpler the better: Highly sensitive 17α-ethinylestradiol sensor based on an unmodified carbon paper transducer
Publication . Torrinha, Álvaro; Carneiro, Pedro; Dias, Diana; Delerue-Matos, Cristina; Morais, Simone
The remarkable features of a carbon fiber paper sensor (CP) were employed for detection of the estrogenic hormone 17α-ethinylestradiol (EE2), considered a contaminant of emerging concern due to its potential ecotoxicity and widespread in the aquatic ecosystems. In this work, an unpreceded CP pre-treatment study was conducted with the (Il)-hexacyanoferrate(III) ion pair, however a bare sensor without pre-treatment revealed higher efficiency on the oxidation of EE2 compared to a chemical and electrochemical pre-treated CP and a gold nanoparticles modified CP, being thus selected for EE2 determinations. The analytical conditions were thoroughly optimized in terms of electrolyte pH (pH 7), differential pulse voltammetry parameters (modulation time 0.003 s, amplitude 0.09 V, interval time 0.1 s and step potential 0.01 V), and analyte preconcentration potential (0.4 V) and time (180 s). The hormone can be determined by the CP in a wide linear range from 0.1 to 1000 nM, achieving a detection limit of 0.14 ± 0.005 nM and an outstanding sensitivity of 1636 ± 232 μA μM−1 cm−2 in the lowest linear zone (0.1–1 nM). The sensor was validated in river water and fish reaching good recoveries (91.2 ± 4.6 to 109.0 ± 7.1%), reproducibility and repeatability. Moreover, the sensor showed high selectivity to EE2 in the presence of several potential interfering compounds and frequently prescribed drugs, though it could not discriminate the similar hormone, 17β-estradiol, being the total concentration obtained in this case. CP-based sensors emerge as efficient electroanalytical tools, suggesting that modification of the surface may not always be beneficial in terms of sensitivity
(Bio)Sensing Strategies Based on Ionic Liquid-Functionalized Carbon Nanocomposites for Pharmaceuticals: Towards Greener Electrochemical Tools
Publication . Torrinha, Álvaro; Oliveira, Thiago M. B. F.; Ribeiro, Francisco W. P.; de Lima-Neto, Pedro; Correia, Adriana N.; Morais, Simone
The interaction of carbon-based nanomaterials and ionic liquids (ILs) has been thoroughly exploited for diverse electroanalytical solutions since the first report in 2003. This combination, either through covalent or non-covalent functionalization, takes advantage of the unique characteristics inherent to each material, resulting in synergistic effects that are conferred to the electrochemical (bio)sensing system. From one side, carbon nanomaterials offer miniaturization capacity with enhanced electron transfer rates at a reduced cost, whereas from the other side, ILs contribute as ecological dispersing media for the nanostructures, improving conductivity and biocompatibility. The present review focuses on the use of this interesting type of nanocomposites for the development of (bio)sensors specifically for pharmaceutical detection, with emphasis on the analytical (bio)sensing features. The literature search displayed the conjugation of more than 20 different ILs and several carbon nanomaterials (MWCNT, SWCNT, graphene, carbon nanofibers, fullerene, and carbon quantum dots, among others) that were applied for a large set (about 60) of pharmaceutical compounds. This great variability causes a straightforward comparison between sensors to be a challenging task. Undoubtedly, electrochemical sensors based on the conjugation of carbon nanomaterials with ILs can potentially be established as sustainable analytical tools and viable alternatives to more traditional methods, especially concerning in situ environmental analysis
Life Cycle Assessment and Life Cycle Cost of an Innovative Carbon Paper Sensor for 17α-Ethinylestradiol and Comparison with the Classical Chromatographic Method
Publication . Martins, Florinda; Torrinha, Álvaro; Delerue-Matos, Cristina; Morais, Simone
Nowadays there is a growing concern with the environment and sustainability, which means that better methods, including pollutants analysis, with less consumption of materials, organic solvents, and energy, need to be developed. Considering the almost inexistent information about the topic, the main goal of this work was to compare the environmental impacts of two analytical methods, a traditional one based on liquid chromatography with fluorescence detection and a newly developed carbon paper sensor. The selected analyte was 17α-ethinylestradiol, which is a contaminant of emergent concern in aquatic ecosystems due to its endocrine disruptor behavior. The life cycle assessment data showed that the sensor detection presents an almost negligible environmental impact when compared with the extraction step (the same for both methods) and the liquid chromatographic determination (roughly 80 times higher than with the sensor). The sensor values for all categories of damage are below 3% of the total method impacts, i.e., 1.6, 1.9, 2.4, and 2.9% for resources, climate change, human health, and ecosystem quality. The extraction represents 98.1% of the sensor environmental impacts (and 99.6% of its life cycle costing) and 38.8% of the chromatographic method. This study evidences the need of developing and applying greener analytical (detection and extraction) strategies
Removal and sensing of emerging pollutants released from (micro)plastic degradation: Strategies based on boron-doped diamond electrodes
Publication . Oliveira, Thiago M.B.F.; Ribeiro, Francisco W.P.; Morais, Simone; de Lima-Neto, Pedro; Correia, Adriana N.
The negative impacts of microplastics on the environment and human health cannot be unnoticed. Several classes of emerging pollutants with endocrine-disrupting properties such as bisphenol A and its analogs, phthalates, among others, have been reported to migrate out of plastics entering the aquatic environment. Thus, this review aims to draw attention to the significant potential of the boron-doped diamond electrode to contribute to the implementation of mitigation actions for microplastic pollutants. The latest studies in the two main fields of the use of the boron-doped diamond electrode, that is, treatment of wastewater by electrochemical oxidation and a as sensor for pollutants monitoring, are herein reviewed and their main findings highlighted.
Application of Nanostructured Carbon-Based Electrochemical (Bio)Sensors for Screening of Emerging Pharmaceutical Pollutants in Waters and Aquatic Species: A Review
Publication . Torrinha, Álvaro; Oliveira, Thiago M. B. F.; Ribeiro, Francisco W.P.; Correia, Adriana N.; Lima-Neto, Pedro; Morais, Simone
Pharmaceuticals, as a contaminant of emergent concern, are being released uncontrollably into the environment potentially causing hazardous effects to aquatic ecosystems and consequently to human health. In the absence of well-established monitoring programs, one can only imagine the full extent of this problem and so there is an urgent need for the development of extremely sensitive, portable, and low-cost devices to perform analysis. Carbon-based nanomaterials are the most used nanostructures in (bio)sensors construction attributed to their facile and well-characterized production methods, commercial availability, reduced cost, high chemical stability, and low toxicity. However, most importantly, their relatively good conductivity enabling appropriate electron transfer rates—as well as their high surface area yielding attachment and extraordinary loading capacity for biomolecules—have been relevant and desirable features, justifying the key role that they have been playing, and will continue to play, in electrochemical (bio)sensor development. The present review outlines the contribution of carbon nanomaterials (carbon nanotubes, graphene, fullerene, carbon nanofibers, carbon black, carbon nanopowder, biochar nanoparticles, and graphite oxide), used alone or combined with other (nano)materials, to the field of environmental (bio)sensing, and more specifically, to pharmaceutical pollutants analysis in waters and aquatic species. The main trends of this field of research are also addressed.

Organizational Units

Description

Keywords

Contributors

Funders

Funding agency

Fundação para a Ciência e a Tecnologia

Funding programme

9471 - RIDTI

Funding Award Number

PTDC/ASP-PES/29547/2017

ID