Repository logo
 
Publication

Novel optical PVC probes for on-site detection/determination of fluoroquinolones in a solid/liquid interface: Application to the determination of Norfloxacin in aquaculture water

dc.contributor.authorSilva, Tâmara I. B.
dc.contributor.authorMoreira, Felismina T. C.
dc.contributor.authorTruta, Liliana A.A.N.A.
dc.contributor.authorSales, M. Goreti F.
dc.date.accessioned2015-10-19T12:46:26Z
dc.date.available2015-10-19T12:46:26Z
dc.date.issued2012
dc.description.abstractA novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.pt_PT
dc.identifier.doi10.1016/j.bios.2012.04.018
dc.identifier.urihttp://hdl.handle.net/10400.22/6748
dc.language.isoengpt_PT
dc.publisherElsevierpt_PT
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S0956566312002345pt_PT
dc.subjectSolid-state optical probept_PT
dc.subjectAquaculturept_PT
dc.subjectAntimicrobialpt_PT
dc.subjectFluoroquinolonespt_PT
dc.subjectNorfloxacinpt_PT
dc.subjectWaterpt_PT
dc.titleNovel optical PVC probes for on-site detection/determination of fluoroquinolones in a solid/liquid interface: Application to the determination of Norfloxacin in aquaculture waterpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage206pt_PT
oaire.citation.startPage199pt_PT
oaire.citation.titleBiosensors and Bioelectronicspt_PT
oaire.citation.volume36pt_PT
person.familyNameMoreira
person.givenNameFelismina
person.identifier1589429
person.identifier.ciencia-idC917-6A46-A270
person.identifier.orcid0000-0003-4237-8952
person.identifier.scopus-author-id23486193000
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication9c13153d-a73a-49ff-b7f6-c9733bc6725e
relation.isAuthorOfPublication.latestForDiscovery9c13153d-a73a-49ff-b7f6-c9733bc6725e

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ART_SalesGoreti6_2012.pdf
Size:
651.6 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: