Repository logo
 
Publication

Ventilação Hospitalar em Ambiente Pandémico

dc.contributor.advisorPereira, Isabel Maria Garcia Sarmento
dc.contributor.authorTeixeira, Joana Filipa Martins
dc.date.accessioned2022-03-03T09:44:33Z
dc.date.available2022-03-03T09:44:33Z
dc.date.issued2021
dc.description.abstractO aparecimento do vírus Covid-19 conduziu a várias mudanças no comportamento dos edifícios, principalmente no funcionamento dos sistemas AVAC (Aquecimento, Ventilação, Ar Condicionado). Os sistemas AVAC, corretamente ajustados, contribuem para mitigar/evitar o risco de transmissão do vírus, o que poderá levar a um aumento dos consumos de energia dos edifícios, visto que os sistemas AVAC irão ter maior esforço no funcionamento para satisfazer as recomendações das entidades de saúde para evitar a transmissão e manter a qualidade do ar interior (QAI) aceitável. O trabalho proposto pretendeu avaliar o impacto das alterações recomendadas nos sistemas AVAC, dimensionar corretamente os equipamentos AVAC tendo em consideração todos os prossupostos e perceber quais os consumos energéticos futuros de um edifício hospitalar. O edifício hospitalar em estudo foi a ampliação das urgências do Centro Hospitalar de Santo Tirso (CHST). A determinação das cargas térmicas de aquecimento e arrefecimento e o cálculo dos consumos energéticos, foram realizados através do software Carrier Hourly Analysis Program (HAP) para duas simulações: situação base (pré-Covid-19) e situação pandémica (Covid-19). Tendo sido realizadas as simulações dos impactos da situação pandémica individualmente, como a: alteração do caudal de 100 % de ar novo; desativação das unidades de recuperação de calor; alteração do nível de filtragem; impacto conjunto. As cargas térmicas obtidas foram ligeiramente diferentes para todas as simulações, possivelmente relacionadas com o aumento da necessidade de controlar a qualidade do ar interior. Calculou-se o Indicador de Eficiência Energética (IEE) para a atribuição da classe do edifício. No entanto, registaram-se diferentes classes energéticas para as duas simulações: situação base (pré-Covid-19) e situação pandémica (Covid-19). A classe energética foi igual a B- e C, respetivamente. Em suma, verificou-se que o aparecimento do vírus Covid-19 aumentou significativamente os consumos de energia e, consequentemente, os custos associados serão mais elevados.pt_PT
dc.description.abstractThe appearance of the Covid-19 virus led to several changes in the behavior of buildings, mainly in the functioning of HVAC (Heating, Ventilation, Air Conditioning) systems. Correctly adjusted HVAC systems contribute to mitigate/avoid the risk of virus transmission, which may lead to an increase in energy consumption in buildings, since HVAC systems will have greater effort in operation to meet the recommendations of the entities to prevent transmission and keep indoor air quality (IAQ) acceptable. The proposed work intended to evaluate the impact of the recommended changes in HVAC systems, correctly dimensioning the HVAC equipment taking into account all the assumptions and understanding the future energy consumption of a hospital building. The hospital building under study was the expansion of the emergency room of the Santo Tirso Hospital Center (STHC). The determination of heating and cooling thermal loads and the calculation of energy consumption were performed using the Carrier Hourly Analysis Program (HAP) software for two simulations: base situation (pre-Covid-19) and pandemic situation (Covid-19). Pandemic situation individually, such as: 100 % fresh air flow change; deactivation of heat recovery units; changing the filtering level; joint impact. The thermal loads obtained were slightly different for all simulations, possibly related to the increased need to control indoor air quality. The Energy Efficiency Indicator (EEI) was calculated for the attribution of the building class. Nevertheless, different energy classes were registered for the two simulations: base situation (pre-Covid-19) and pandemic situation (Covid19). The energy class was equal to B- and C, respectively. In short, it was found that the appearance of the Covid-19 virus significantly increased energy consumption and, consequently, the associated costs will be higher.pt_PT
dc.identifier.tid202936910pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.22/20104
dc.language.isoporpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt_PT
dc.subjectAVAC
dc.subjectEnergia
dc.subjectCargas térmicas
dc.subjectClasse energética
dc.subjectCovid-19
dc.subjectHospital
dc.subjectHVAC
dc.subjectEnergy
dc.subjectThermal loads
dc.subjectEnergy class
dc.titleVentilação Hospitalar em Ambiente Pandémicopt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado em Engenharia Mecânica – Energiapt_PT

Files

Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
DM_JoanaTeixeira_2021_MEM.pdf
Size:
5.68 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
license1.txt
Size:
1.74 KB
Format:
Item-specific license agreed upon to submission