Repository logo
 
Publication

New and low cost plastic membrane electrode with low detection limits for sulfadimethoxine determination in aquaculture waters

dc.contributor.authorAlmeida, Sofia A. A.
dc.contributor.authorMontenegro, M.C.B.S.M.
dc.contributor.authorSales, M. Goreti F.
dc.date.accessioned2015-10-16T12:11:21Z
dc.date.available2015-10-16T12:11:21Z
dc.date.issued2013
dc.description.abstractSulfadimethoxine (SDM) is one of the drugs, often used in the aquaculture sector to prevent the spread of disease in freshwater fish aquaculture. Its spread through the soil and surface water can contribute to an increase in bacterial resistance. It is therefore important to control this product in the environment. This work proposes a simple and low-cost potentiometric device to monitor the levels of SDM in aquaculture waters, thus avoiding its unnecessary release throughout the environment. The device combines a micropipette tip with a PVC membrane selective to SDM, prepared from an appropriate cocktail, and an inner reference solution. The membrane includes 1% of a porphyrin derivative acting as ionophore and a small amount of a lipophilic cationic additive (corresponding to 0.2% in molar ratio). The composition of the inner solution was optimized with regard to the kind and/or concentration of primary ion, chelating agent and/or a specific interfering charged species, in different concentration ranges. Electrodes constructed with inner reference solutions of 1 × 10−8 mol/L SDM and 1 × 10−4 mol/L chromate ion showed the best analytical features. Near-Nernstian response was obtained with slopes of −54.1 mV/decade, an extraordinary detection limit of 7.5 ng/mL (2.4 × 10−8 mol/L) when compared with other electrodes of the same type. The reproducibility, stability and response time are good and even better than those obtained by liquid contact ISEs. Recovery values of 98.9% were obtained from the analysis of aquaculture water samples.pt_PT
dc.identifier.doi10.1016/j.jelechem.2013.09.029
dc.identifier.urihttp://hdl.handle.net/10400.22/6728
dc.language.isoengpt_PT
dc.publisherElsevierpt_PT
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S1572665713004360pt_PT
dc.subjectLowering limit of detectionpt_PT
dc.subjectIon-selective electrodespt_PT
dc.subjectInner reference solutionpt_PT
dc.subjectLiquid-contact electrodespt_PT
dc.subjectElectrode body of micropipette tipspt_PT
dc.titleNew and low cost plastic membrane electrode with low detection limits for sulfadimethoxine determination in aquaculture waterspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage45pt_PT
oaire.citation.startPage39pt_PT
oaire.citation.titleJournal of Electroanalytical Chemistrypt_PT
oaire.citation.volume709pt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ART_Sales_2013.pdf
Size:
512.9 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: