dc.description.abstract | An electrochemical sensor has been developed for the determination of the herbicide bentazone, based on a GC electrode modified by a combination of multiwalled carbon nanotubes (MWCNT) with b-cyclodextrin (b-CD) incorporated in a polyaniline film. The results indicate that the b-CD/MWCNT modified GC electrode exhibits efficient electrocatalytic oxidation of bentazone with high sensitivity and stability. A cyclic voltammetric method to determine bentazone in phosphate buffer solution at pH 6.0, was developed, without any previous extraction, clean-up, or derivatization steps, in the range of 10–80 mmolL 1, with a detection limit of 1.6 mmolL 1 in water. The results were compared with those obtained by an established HPLC technique. No statistically significant differences being found between both methods. | por |
dc.identifier.doi | 10.1002/elan.201300230 | |
dc.identifier.issn | 1521-4109 | |
dc.identifier.uri | http://hdl.handle.net/10400.22/3525 | |
dc.language.iso | eng | por |
dc.peerreviewed | yes | por |
dc.publisher | Wiley | por |
dc.relation.ispartofseries | Electroanalysis; Vol. 25, Issue 10 | |
dc.relation.publisherversion | http://onlinelibrary.wiley.com/doi/10.1002/elan.201300230/abstract | por |
dc.subject | Herbicides | por |
dc.subject | Bentazone | por |
dc.subject | Voltammetric sensors | por |
dc.subject | b-Cyclodextrin | por |
dc.subject | Carbon nanotubes | por |
dc.title | Electrochemical determination of the herbicide bentazone using a carbon nanotube b-Cyclodextrin modified electrode | por |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 2366 | por |
oaire.citation.issue | Issue 10 | |
oaire.citation.startPage | 2360 | por |
oaire.citation.title | Electroanalysis | por |
oaire.citation.volume | Vol. 25 | |
person.familyName | Garrido | |
person.givenName | Jorge | |
person.identifier.orcid | 0000-0001-8981-231X | |
person.identifier.scopus-author-id | 7202779733 | |
rcaap.rights | openAccess | por |
rcaap.type | article | por |
relation.isAuthorOfPublication | f548e711-c68e-4c49-9471-9923c047116d | |
relation.isAuthorOfPublication.latestForDiscovery | f548e711-c68e-4c49-9471-9923c047116d |