The importance of drop coalescence in a stirred liquid-liquid extraction (Kühni) column

Utilize este identificador para referenciar este registo.
Nome:Descrição:Tamanho:Formato: 
COM_GuimaraesMML__DEQ_1999_ISEC.pdf2.04 MBAdobe PDF Ver/Abrir

Orientador(es)

Resumo(s)

Experiments performed at low agitation speeds, using the high interfacial tension toluene (dispersed)-water (continuous) system, in a pilot plant Kühni column, show that coalescence events are generally present and cannot be neglected in column-type liquid-liquid contactors, especially when the goal is the accurate modelling of the transient processes for control purposes. In this work, the features of this behaviour and the applicability to this situation of a new, fast and precise, recently developed algorithm, 1 that describes the dynamic behaviour of an agitated column, is illustrated. Experiments were performed at low agitation speeds, using the above high interfacial tension system. The simulations show reasonably good agreement with the experimental results and provide insight on the underlying behaviour mechanisms and important guidelines for the accurate modelling of the dynamics of the column.

Descrição

Palavras-chave

Kühni column drop coalescence drop breakage column dynamics

Contexto Educativo

Citação

Gomes, M. L. A. C. N., Guimarães, M. M. L., Zamponi, G., Stichlmair, J. Regueiras, P. F. R. & Cruz-Pinto, J. J. C. (1999, July 1). The importance of drop coalescence in a stirred liquid-liquid extraction (Kühni) column. In Cox, M., Hidalgo, M. & Valiente, M. (Eds.) Solvent extraction for the 21st century: Proceedings of ISEC’99 (Volume 1). (pp.487-492). Society of Chemical Industry.

Projetos de investigação

Unidades organizacionais

Fascículo

Editora

Society of Chemical Industry

Licença CC

Sem licença CC