Repository logo
 
Publication

Determination of Microcystin-LR in waters in the subnanomolar range by sol–gel imprinted polymers on solid contact electrodes

dc.contributor.authorQueirós, Raquel B.
dc.contributor.authorNoronha, João P. C.
dc.contributor.authorMarques, P.V.S.
dc.contributor.authorFernandes, João S.
dc.contributor.authorSales, M. Goreti F.
dc.date.accessioned2015-10-19T12:47:10Z
dc.date.available2015-10-19T12:47:10Z
dc.date.issued2012
dc.description.abstractThe present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.pt_PT
dc.identifier.doi10.1039/C2AN35141B
dc.identifier.urihttp://hdl.handle.net/10400.22/6750
dc.language.isoengpt_PT
dc.publisherAnalystpt_PT
dc.relation.publisherversionhttp://pubs.rsc.org/en/Content/ArticleLanding/2012/AN/c2an35141b#!divAbstractpt_PT
dc.titleDetermination of Microcystin-LR in waters in the subnanomolar range by sol–gel imprinted polymers on solid contact electrodespt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage2444pt_PT
oaire.citation.startPage2437pt_PT
oaire.citation.titleAnalystpt_PT
oaire.citation.volume137pt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ART_SalesGoreti8_2012.pdf
Size:
488.03 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: