  • Amperometric enzyme sensor for the rapid determination of histamine
    Publication . Torre, Ricarda; Costa Rama, Estefanía; LOPES, Paula; Nouws, Henri; Delerue-Matos, Cristina
    The concentration of histamine, a biogenic amine, in fish is considered a fish spoilage indicator. Therefore, the development of a rapid-response and portable tool that allows its on-site analysis is very interesting since the consumption of high amounts of histamine causes scombroid poisoning. Thus, in this work a simple enzymatic sensor for the determination of histamine, based on a screen-printed carbon electrode and the enzyme diamine oxidase, was developed. The enzyme was immobilized on the electrode surface through a simple cross-linking procedure employing glutaraldehyde and bovine serum albumin. Chronoamperometry was used as the detection technique; the sensor showed a short response time (60 s, -0.3 V) and the measurements were performed by only using 40 μL of sample solution. The sensor provides an useful linear range (between 1 and 75 mg L-1 in fish extract), excellent reproducibility (RSD = 2.6%) and is reusable for up to 7 measurements. The feasibility of the sensor was tested performing histamine analysis in fish extracts achieving recovery values of 103%.
  • Disposable electrochemical immunosensor for analysis of cystatin C, a CKD biomarker
    Publication . LOPES, Paula; Costa Rama, Estefanía; Beirão, Idalina; Nouws, Henri; Santos-Silva, Alice; Delerue-Matos, Cristina
    Specific monitoring of cystatin C (CysC) levels in biological fluids is critical for diagnosis, treatment and mechanistic understanding of a spectrum of diseases, particularly chronic kidney disease (CKD). Despite evidences that CysC correlates with the high risk and/or progression of CKD, its use in clinical practice is still scarce. In this context, we report the development of a simple and sensitive immunosensor for the detection of CysC. The biosensor combines the technology of cost-effective screen-printed electrodes with the high specificity of a sandwich immunoassay. Optimized conditions showed that the sensor operates in a linear range between 10 and 100 ng mL-1, with a detection limit and a sensitivity of 6.0 ng mL-1 and 6.4 ± 0.3 μA ng mL-1 cm-2, respectively. Moreover, the sensor provided precise results (RSD ≤ 6.2%) and the quantification of CysC in CKD serum samples revealed to be in agreement with the values obtained by a particle-enhanced nephelometric immunoassay. In this light, the proposed immunosensor qualifies for clinical application, constituting a step forward in the development of fast, sensitive and cost-effective diagnostic tools that can improve the current medical care settings of CKD patients.