- Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levelsPublication . Barreiros, Luisa; Amoreira, Júlia L.; Machado, Sandia; Fernandes, Sara R.; Silva, Eduarda M.P.; Sá, Paula; Kietaibl, Sibylle; Segundo, Marcela A.Tranexamic acid (TXA) is an antifibrinolytic drug, with the ability to inhibit lysine binding at plasminogen receptors, used in adult trauma patients with on-going or at risk of significant haemorrhage. To understand the pharmacokinetics and pharmacodynamics of this drug in variable age groups undergoing surgeries with high blood loss, effective methods for determination of TXA in biological samples at sub-μg mL−1 are still required. We describe herein the development and validation of a method based on ultra-high performance liquid chromatography coupled to triple quadrupole-tandem mass spectrometry to quantify TXA in human plasma. An inexpensive, simple and efficient sample clean-up was implemented, not requiring matrix-matching calibration. Sample preparation consisted in protein precipitation using acetonitrile containing 0.5% (v/v) formic acid, followed by hydrophilic interaction based chromatographic separation, with elution in isocratic mode using a combination of acetonitrile and water (75:25, v/v), with quantification of TXA based on selected reaction monitoring. Good linearity was achieved (r2 > 0.997) for TXA concentrations ranging from 30 to 600 ng mL−1, with LOD of 18 ng mL−1 in plasma. The developed method proved to be selective, sensitive, accurate (96.4–105.7% of nominal values) and precise (RSD ≤ 4.5%). TXA was found to be stable in plasma extracts standing 24 h at room temperature (20 °C) or in the autosampler, and after three freeze-thawing cycles. Mean recovery values of TXA spiked plasma samples were ≥91.9%. No significant matrix effects were observed. The proposed methodology was successfully applied to the clinical study of plasma samples recovered during scoliosis surgery of pediatric patients pretreatment with TXA.
- Quantification of tranexamic acid in human plasma: development and validation of UHPLC-MS/MS methodPublication . Barreiros, Luisa; Amoreira, Júlia L.; Machado, Sandia; Fernandes, Sara R.; Silva, Eduarda M. P.; Sá, Paula; Kietaibl, Sibylle; Segundo, Marcela A.; Fernandes, SaraTranexamic acid (TXA), an antifibrinolytic drug with the ability to inhibit lysine binding at plasminogen receptors, can be used in different settings such as trauma, cardiac surgery, major orthopedic surgery, obstetric when perioperative bleeding is concerned [1]. Effective methods for determination of TXA in biological samples are still required to understand the pharmacokinetics and pharmacodynamics of this drug in variable age groups undergoing surgeries with high blood loss [2]. The development and validation of a method based on ultra-high performance liquid chromatography coupled to triple quadrupole-tandem mass spectrometry (UHPLCMS/MS) to quantify TXA in human plasma is described herein. A simple, inexpensive and efficient sample treatment involving protein precipitation with acetonitrile containing 0.5% (v/v) formic acid was implemented using volumes within the microliter range. Separation was achieved using a hydrophilic interaction based stationary phase and ammonium bicarbonate in the mobile phase that permitted a more efficient separation of the analyte from the matrix interferences, thus reducing matrix effects and increasing method sensitivity. The method was validated according to the European Medicines Agency guideline [3]. Excellent linearity was achieved (r2 > 0.997) for TXA concentrations ranging from 30 to 600 ng mL-1 with LOD and LOQ of 3 and 6 ng mL-1 in plasma extracts, respectively. The developed method proved to be selective, sensitive, accurate (96.4-105.7% of nominal concentration values) and precise (RSD ≤ 4.5%).