dc.contributor.authorSales, M. Goreti F.-
dc.contributor.authorTomás, José F. C.-
dc.contributor.authorLavandeira, Sandra R.-
dc.date.accessioned2013-11-29T11:13:22Z-
dc.date.available2013-11-29T11:13:22Z-
dc.date.issued2006-
dc.identifierhttp://dx.doi.org/10.1016/j.jpba.2006.03.027-
dc.identifier.urihttp://hdl.handle.net/10400.22/3018-
dc.description.abstractNew chlorpromazine selective electrodes with a tubular arrangement and no internal reference solution are proposed. Selective membranes are of poly(vinyl chloride) (PVC) with the tetraphenylborate•chlorpromazine (TPB•CPZ) ion-exchanger dissolved in o-nitrophenyl octyl ether (oNPOE). Analytical features of the electrodes were evaluated on a single-channel flow assembly having 500 µl injection volumes and flow-rates of 4.5 ml min−1. For a carrier solution of 3.3×10−3Min sodium sulphate, Nernstian responsewas observed over the concentration range 1.0×10−5 to 1.0×10−2 M. Average slopes were about 59mVdecade−1 and squared correlation coefficients were >0.9984. Slight hiper-Nernstian behaviour was observed in buffer solutions of 4.4 pH; average slopes were of 62.06mVdecade−1. The electrode displayed a good selectivity for CPZ, with respect to, several foreign inorganic and organic species. The selective electrodes were successfully applied to the analysis of pure solutions and pharmaceutical preparations. Proposed method allows the analysis of 84 samples h−1, producing wastewaters of low toxicity. The proposed method offers the advantage of simplicity, accuracy, applicability to coloured and turbid samples, and automation feasibility.por
dc.language.isoengpor
dc.publisherElsevierpor
dc.relation.ispartofseriesJournal of Pharmaceutical and Biomedical Analysis; Vol. 41, Issue 4-
dc.rightsclosedAccesspor
dc.subjectChlorpromazinepor
dc.subjectIon-selective electrodespor
dc.subjectFlow injection analysispor
dc.subjectPotentiometrypor
dc.subjectPharmaceuticalspor
dc.titleFlow injection potentiometric determination of chlorpromazinepor
dc.typearticlepor
dc.peerreviewedyespor
degois.publication.firstPage1280por
degois.publication.lastPage1286por
degois.publication.titleJournal of Pharmaceutical and Biomedical Analysispor
degois.publication.volume41por
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S0731708506002767#por
Aparece nas colecções:ISEP – GRAQ – Artigos

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
ART_GoretiSales_2006_GRAQ.pdf96,21 kBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.